MAN - PAV4 - REV: Original | D. Installation
8
D.4 Air and Power Connections
1. Install the air pressure line to the 1/4” male pipe-threaded fitting provided on the back of the control cabinet.
CAUTION: Use a regulated air supply of 340 to 350 psi (2.34 to 2.41 MPa). Do not exceed 350 psi
(2.41 MPa) or the PAV’s performance may be impaired by excessive pressure.
2. A connector is provided with the unit. This connector may be changed if it does not match the available receptacle.
Power requirements are: 230-240 VAC, ±5 V, 10 amp, single-phase, 50/60 Hz.
CAUTION: The PAV requires a minimum of 230 VAC to operate correctly. Check the supply
voltage to ensure it is 230-240 VAC. If the supply voltage is less than 230 VAC, a Step-Up or
Buck-Boost transformer can be supplied to provide the proper operating voltages. Contact ATS.
Be prepared to provide the ATS Service representative with information about the available AC
voltage so the correct transformer wiring configuration can be provided.
CAUTION: The PAV and control system must be grounded according to national and local code
requirements.
Figure D.1: Pan Holder Leveling
Figure D.2: Power connector