17 05.31.13
points in the transmission buffer that are more than nine days apart as may be the case
with prolonged STS periods.
STS is only available on SNs 030534 and higher or collars refurbished after May 1, 2011.
Section 9 Remote Scheduling
There are several scheduling options for the GPS Collar that can be changed remotely: GPS fix
schedule, satellite transmission schedule, maximum GPS fix duration, and mortality. To change
any of these settings:
1.
From the ATSFixes for Satellite Collars main screen, click on the remote command
option that applies:
-Change Fix Schedule Via Satellite: change GPS collar’s current GPS fix schedule
-Change Fix Duration Via Satellite: change the maximum time that the GPS collar
will attempt a GPS fix before timing out
-Change Mort Schedule Via Satellite: change the length of inactivity before mortality
is detected/declared
-Change Sat Tx Interval Via Satellite: change the schedule of email transmission
attempts
2.
Follow the instructions on the following screen and click on the Done button to proceed.
Click on Cancel to cancel the request.
3.
Enter the serial number of the GPS Collar you wish to change and click on Done.
4.
A dialogue box will open next. If your computer’s e-mail client is Microsoft Outlook and
it is running under the email account registered for the collar, then no further action is
necessary. If this is not the case, the remote command must be manually emailed using
the instructions provided in the dialog box using the registered email account.
You should receive an email indicating whether or not request was successfully received. If you
receive an error email or no email and need further assistance, please contact ATS.
Once the remote command is received correctly, the GPS Collar will change its schedule the next
time the collar successfully transmits an email. Only one remote command can be sent for each
email. If you wish, you may send multiple remote commands to be processed later by the collar
but you must wait until you receive a confirmation email for each request before you send
another request.