ATS DWS-25 Installation, Operation And Maintenance Manual Download Page 15

15

Notes

DWS © 20

20

 • www.aquat.com        

Summary of Contents for DWS-25

Page 1: ...nstallation Operation and Maintenance Manual CAUTION Read and Follow all safety rules and operating instructions before first use of product MODEL DWS 25 DRINKING WATER STERILIZER Ultraviolet Disinfec...

Page 2: ...2...

Page 3: ...Function Description 5 Installation Diagram 6 Sanitation Procedure 7 8 Maintenance 9 Wiring Diagrams 10 Parts Breakdown 11 Troubleshooting 12 Sterile Water Sample Procedures 13 Specifications 14 Warr...

Page 4: ...an unsafe condition 7 Intended for indoor use Do not install this disinfection system where it will be exposed to the weather Do not store this disinfection system where it will be exposed to temperat...

Page 5: ...rated capacity of the unit The DWS series has an unique design with an ultraviolet germicidal lamp housed within a single quartz sleeve surrounded by a stainless steel pressure chamber The chamber is...

Page 6: ...support Use anchors with screws for sufficient support not included A lock nut secures the mounting bracket to the U V chamber If your piping system is subject to impulse pressure resulting in a water...

Page 7: ...the well and storage tank should be treated with a strong chlorine solution to destroy disease organisms All pipelines and fixtures in the distribution system should be rinsed and flushed with chlori...

Page 8: ...the water if necessary Plumbing Line Sanitation Only When installing an ultraviolet disinfection system a pre filter with sump may serve as a source to sanitize the water lines only For whole system d...

Page 9: ...ng on any threaded part of the nipple Hand tighten each compression nut to form a compressionsealaroundthequartzsleeve Avoidovertightening the nuts which may cause a fracture on the end of the quartz...

Page 10: ...10 Wiring Diagram DWS 2020 www aquat com...

Page 11: ...11 Parts Breakdown DWS 2020 www aquat com...

Page 12: ...disconnected Check replace or outlet defective Defective U V lamp Replace Defective lamp ballast Check output voltage Replace ballast Loose open circuit wire Trace out and repair Leak at quartz nippl...

Page 13: ...erile bottle or sterile container being used Holding the cap in a down position the operator should then hold his breath while taking the sample so as to avoid oral contamination of the sample The ope...

Page 14: ...14 Specifications DWS 2020 www aquat com...

Page 15: ...15 Notes DWS 2020 www aquat com...

Page 16: ...16 Warranty DWS 2020 www aquat com...