<Table 1>
5. Transport and Storage
In the process of transportation, handle carefully and
keep upright to prevent damage of the product packing.
Wrapped equipment should not be in open air for a long time,
and shall be placed in a well-ventilated and non-corrosive
gases warehouse. When equipment needs temporary storage,
rainproof measures should be taken.
6. Installation and Debugging
Any erroneous installation, adjustment, refit, overhaul
or maintenance may cause property damage or personal
injury. The work shall be performed by authorized and
licensed technicians, otherwise the manufacturer has the
right not to provide warranty service;
Only be installed in accordance with the local code. If
no similar standard, you should conform to the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, the National Gas
Installation Code, CSA-B149.1, or the L.P. Gas
Installation Code, CSA-B149.2 as applicable;
The appliance individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in
excess of 1/2psi (3.45kPa).
Model
#of
burners
and
control
method
Gas
Species
Intake-
tube
pressure
(
in.W.C.
)
Per
BTU
B.T.U.
/h
Total
BTU
B.T.U./
h
Nozzl
e No.
ACHP-2
2 pieces
Independe
nt
control
Natural
Gas
4
32,000
64,000
NG37
L.P.
Gas
10
32,000
64,000
LPG51
ACHP-4
4 pieces
Independe
nt
control
Natural
Gas
4
32,000
128,000
NG37
L.P.
Gas
10
32,000
128,000
LPG51
ACHP-6
6 pieces
Independe
nt
control
Natural
Gas
4
32,000
192,000
NG37
L.P.
Gas
10
32,000
192,000
LPG51
6