Before using the stove for the first time, please use a
mild detergent to wipe it clean. Do not use corrosive or
abrasives detergent.
Turn the burners on about 15-20 minutes before broiling
for preheating, according to the cooking requirement to
adjust the flame size.
Notice: When first preheating, the furnace will smoke
above. This is caused by protective lipids on the grates and
other parts are heated, it is normal, and it will be
eliminated after the power up to the maximum for burning an
hour.
8.5
、
Exchange main fire nozzle to switch gas source
Remove control panel, cooking grates, the pilot light
head, and burner, remove main fire nozzle with proper open
spanner, exchange nozzle of another gas source, nozzle no
refer to TABLE 1, then screw it. Reinstall burner, the pilot
light head, cooking grates and control panel in proper
order.
Caution: Each main fire orifice of the burner has been
installed before delivery, normal use without adjustment
but only switching gas. Adjust only by authorized and
licensed technicians. When you converse the gas source,
exchange the corresponding pressure maintaining valve
which installed on air intake.
8.6
、
Adjust air input
Remove control panel, unscrew damper solid screw(Fig.6),
revolve damper left to right (Fig.7), meanwhile, observe
flame, to adjust an appropriate opening degree. Then screw
damper solid screw, make sure the equipment will not get
loose in the process of moving and translation. Reinstall
control panel.
Caution: Each burner damper has been adjusted before
delivery (once air input), normal use without adjustment
but only switching gas. Adjust only by authorized and
licensed technicians.
Fig.5 Fig.6
Fig.7
11