Atos ACHP-2 Operating Instructions Manual Download Page 11

Before using the stove for the first time, please use a 

mild detergent to wipe it clean. Do not use corrosive or 
abrasives detergent.

Turn the burners on about 15-20 minutes before broiling 

for preheating, according to the cooking requirement to 
adjust the flame size.

Notice: When first preheating, the furnace will smoke 

above. This is caused by protective lipids on the grates and 
other parts are heated, it is normal, and it will be 
eliminated after the power up to the maximum for burning an 
hour.

8.5

Exchange main fire nozzle to switch gas source

Remove control panel, cooking grates, the pilot light 

head, and burner, remove main fire nozzle with proper open 
spanner, exchange nozzle of another gas source, nozzle no 
refer to TABLE 1, then screw it. Reinstall burner, the pilot 
light head, cooking grates and control panel in proper 
order. 

Caution: Each main fire orifice of the burner has been 
installed before delivery, normal use without adjustment 
but only switching gas. Adjust only by authorized and 
licensed technicians. When you converse the gas source, 
exchange the corresponding pressure maintaining valve 
which installed on air intake. 

8.6

Adjust air input

Remove control panel, unscrew damper solid screw(Fig.6), 

revolve damper left to right (Fig.7), meanwhile, observe 
flame, to adjust an appropriate opening degree. Then screw 
damper solid screw, make sure the equipment will not get 
loose in the process of moving and translation. Reinstall 
control panel.

Caution: Each burner damper has been adjusted before 
delivery (once air input), normal use without adjustment 
but only switching gas. Adjust only by authorized and 
licensed technicians.

  

  

          Fig.5                    Fig.6                  
Fig.7

 

11

Summary of Contents for ACHP-2

Page 1: ...is product correctly to make the product perform ideally and to avoid hazards Models ACHP 2 ACHP 4 ACHP 6 Dear customers and users Thank you for purchasing our products In order to be able to better u...

Page 2: ...tinguish any open flame If odor continues keep away from the appliance and immediately call your gas supplier or your fire department Gas Countertop Hot Plates Cooktop s The Installation Operation and...

Page 3: ...h appropriate instructions and sufficient safety 2 Brief Instructio n The product is a series of gas hot plates in our company production which is novel designed reasonable structured convenient opera...

Page 4: ...manufacturers Accidents caused by force majeure Not strictly comply with related guide of this instruction by any reason 4 Parameter Specification s 4 1 Outline Dimensions in ACHP 2 ACHP 4 4...

Page 5: ...6 4 2 Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4 Natural Gas W C and 10 L P Gas W C The external thread of product s intake tube is 3 4 inche...

Page 6: ...d in accordance with the local code If no similar standard you should conform to the National Fuel Gas Code ANSI Z223 1 NFPA 54 the National Gas Installation Code CSA B149 1 or the L P Gas Installatio...

Page 7: ...d comply with all codes of the National Fire Protection Association Inc when it comes to requirements for installation of equipment Screw 4 adjustable stainless steel legs in the tapping hole with fou...

Page 8: ...needle type pressure joint screw arbor Important must screw joint screw arbor to prevent gas escape 6 2 Debuggin g It s very important to debug the new stove Through the comprehensive system test of e...

Page 9: ...repair it Do not take apart any spare parts without authorization Never change any other parts without authorization to this equipment otherwise may cause hazards and the manufacturer has the right n...

Page 10: ...ghting the pilot light then the main fire burner is lighted by the pilot light The power of burner increases as revolving angel increases When knob reaches to burner is in the maximum power Fig 4 Fig...

Page 11: ...LE 1 then screw it Reinstall burner the pilot light head cooking grates and control panel in proper order Caution Each main fire orifice of the burner has been installed before delivery normal use wit...

Page 12: ...in a well ventilated area Comprehensively check the equipment at least once every year by authorized and licensed technicians The product is made of 90 metals and can not be discarded everywhere Deal...

Page 13: ...he main fire s distance is too far 4 Adjust the distance of them 5 Flame is too low 5 Adjust the height of the pilot light Close gas and heard a sound of fire 1 Insufficient gas pressure in pipe 1 Con...

Page 14: ...intake ensure gas mark Fig 9 on the plastic core whether match with connected gas source if not then pull out the plastic core and change another head insert it again The same as exchanging gas source...

Page 15: ...oducts have the advantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistan...