background image

Industrial IoT Remote I/O   

IO5202 Series

Version 1.1

Updated in October, 2021

P/N : 89900584G

www.atoponline.com

+ 886-3-5508137 
+ 886-3-5508131 

Inside the package you will find the following items:

■ Industrial IoT remote x 1

■ 3-Pin lockable terminal block for power x 1 

■ 10-Pin I/O terminal blocks x 2

■ 5-Pin lockable terminal block for serial port x 1 (-TB models only)
■ Installation guide with warranty card x 1

Never install or work on electrity or cabling during periods of lightning activity. 

Never connect or disconnect power when hazardous gases are present.

Warning: Hot surface, do not touch. RESTRICTED ACCESS AREA: The equipment 

should only be installed in a Restricted Access Area.

Indoor

Indoor

This equipment should be installed indoors and not connected directly with 

equipment installed outdoors.

1. Grounding Screw

2. Terminal for Power
3. Frame Ground
4. Reset Button

1

3

4

2

V+

F.G.

IO5202-DB Series Front View

IO5202-TB Series Front View

PWR RUN

TX RX

COM

LAN2

LAN1

2

3

4

5

6

8

7

1

PWR RUN

TX RX

COM

LAN2

LAN1

COM

7

2

3

4

5

6

9

1

1. System Power LED
2. System Run LED
3. COM LED-TX

4. COM LED- RX

5. 10/100 Ethernet Port 2
6. 10/100 Ethernet Port 1

7. I/O Port

8. TB-COM Port
9. DB-COM Port 

Once the plate is firmly in place, proceed to mount the 

whole device as shown in (Fig.2). Refer to (Fig. 3) if 

you want to remove the device from the DIN-Rail.

2. 

Connet the device to the LAN (switch or PC, depending on the case), taking 

care  when  using  the  RJ-45  connector. Afterwards,  you  can  proceed  to  the 

device’s settings.

3. 

4. 

Although  internal  grounding  has  been  done  inside,  hazardous 

ESD  can  come  into  contact  and  damage  your  equipment.  In 

order  to  ensure  overall  maximum  performance  and  to  protect 

your device, it is still strongly advised to ground the device 

properly. 

On  the  power  terminal  block,  there  is  a  terminal  for  Frame 

Ground. You can connect it either to grounding or to the ground

-

ing screw next to the terminal block (the one chosen should be 

connected at all times) (Fig. 4).

1

2

(Fig. 3)

1

2

(Fig. 2)

■  The openings on the device's sides are for heat dissipation.

Never obstruct, cover, or try to insert anything through them.

Color

State

LED

Description

Green

On
Off

PWR is connected
PWR is disconnected

PWR

Green

On
Off

System is booted up and running
System is still booting up or powered off

RUN

Green

Blinking

Off

COM 1 is transmitting
COM 1 is not transmitting

TX COM

Green

Blinking

Off

COM 1 is receiving
COM 1 is not receiving

RX COM

Power input: 12 to 48 VDC; 0.8A max

If you have purchased the wall mount kit, proceed to place 

the screws on the back of the device as shown in (Fig. 1).

1. 

Wall mount screw specifications: M3 0.5p

Screw depth: 4 mm (Max) 

Screws x 4 pcs

(Fig. 1)

V+

F.G.

(Fig. 4)