36W LED Backlit Panel 300 x 1200
INSTALLATION SHEET
LED Panel
AT6021/312 - SER II
Product Specification
Voltage
220-240V~ 50Hz
Wattage
36W
Light colour options
Cool white
Daylight
Colour temperature
4000K
5700K
Lumen output
3680lm
3560lm
Finish
White
Colour rendering index
> 80
Dimmable
No
Warranty
3Y/15000Hr*
Working temperature
-10°C – 40°C
IP Rating
IP40
Electrical classification
Class II
This product may contain substances that can be hazardous to the environment if not disposed of properly. Electrical and
electronic equipment should never be disposed of with general household waste but must be separated of it’s correct
treatment and recovery. Where possible recycle your packaging. Please keep these instructions safe for future reference.
Product Range
SKU
Code
Description
12625
AT6021/306/CW - SER II
20W LED Backlit Panel
300 x 600 - 4000K
12626
AT6021/306/DL - SER II
20W LED Backlit Panel
300 x 600 - 5700K
12627
AT6021/312/CW - SER II
36W LED Backlit Panel
300 x 1200 - 4000K
12628
AT6021/312/DL - SER II
36W LED Backlit Panel
300 x 1200 - 5700K
12629
AT6021/606/CW - SER II
36W LED Backlit Panel
600 x 600 - 4000K
12630
AT6021/606/DL - SER II
36W LED Backlit Panel
600 x 600 - 5700K
12631
AT6021/612/CW - SER II
60W LED Backlit Panel
600 x 1200 - 4000K
12632
AT6021/612/DL - SER II
60W LED Backlit Panel
600 x 1200 - 5700K
IMPORTANT INFORMATION
•
Luminaires must be installed and fitted by a licensed
electrician strictly in accordance with the current
revision of AS/NZS 3000 - Electrical installations
(Australia/ New Zealand wiring rules).
•
Do not install this product on damp or newly plastered
ceilings.
•
Do not connect LEDs directly to 230V, use the power
equipment.
•
Luminaires design stipulates a normal usage 16 hours
for commercial applications.
•
Non-user replaceable light source: Light source
contained in this luminaire shall only be replaced by
the manufacturer or his service agent or similar
qualified person.
*3Y/15000Hr operation time (whichever arrives first) subject to all Warranty Conditions
1195mm
295mm
34mm
Isolate mains power.
FIG. 1
Restore mains power.
FIG. 5
Installation
Read instructions and check you have all the tools and accessories to
complete the installation correctly.
1. Isolate the mains power supply before commencing installation (Fig. 1)
2. Feed the mains cable through ceiling recess and plug into the mains
supply. (Fig. 2)
4. Insert panel and driver through ceiling recess (Fig. 4), and secure in
location. Panel should sit flush against the T-bar ceiling grid (as shown
in Fig. 4), and driver should sit on ceiling adjacent to panel.
Note, always ensure driver and panel are not covered by insulation.
5. Reconnect mains power and switch on to operate (Fig. 5)
Insert driver into ceiling followed
by the panel.
FIG. 3
Panel should sit flush against,
and supported by the T-Bar grid.
FIG. 4
T-bar ceiling grid
Feed driver mains cable through ceiling
recess and plug into mains supply.
FIG. 2