Hot Water

 

on Demand

6

This appliance must be EARTHED.
The EARTH continuity conductor of the electrical 

installation must be effectively connected electrically 

to all exposed metal parts of other appliances in the 

room in Which the heater installed.

SWITCH OFF at mains before carrying out any electrical work.
Refer to the Electrical Loading Table (Table 1) for the correct 

cable size.

DO NOT install this product if the line voltage is lower than 175V.

1.  Use  double  coated  flexible  cable  having  nominal  cross-

sectional area between 4 and 6 mm

2

. (IEC/EN 60335-1).

2.   Lead the power cable from the circuit breaker to a “ON/OFF” 

double bipolar switch outside the bathroom, then lead a cable 

connected to terminal block inside the unit (fig.5).

Note: Conduit entry can only from rear.

3.  Connect  the  cable  to  terminal  block  and  fully

 tighten

 them 

(insure  no  cable  insulation  is  trapped  under  the  screws)  as 

follow: (fig.5) 

BROWN or RED FOR LIVE (L)

 

 

BLUE or BLACK for NEUTRAL (N)

 

 

GREEN or Green/ Yellow for EARTH ( ).

The cable clamp must be used to secure the cable. (fig.6)

4.  Check the wiring connection is tightens and correct then close 

the front cover. When close back the front cover , please take 

note the below procedure:

•  To  ensure  the  correct  position,  turn  the  temperature  knob 

insert to OFF position as shown in fig.8. (At the heater base).

•  To install the front cover, turn the temperature control knob 

to OFF position to align with the knob insert as shown in fig.8 

(At the front cover).

For pump models, the same align procedure is apply to both 

pump speed VR insert And pump knob.

5.  Fix back the screws A & B. (fig. 7)

Do not switch on the electricity supply until the cover has been 

fitted.

Fig.5

Fig.6

Fig.7

Fig.8

A

B

Electrical connection

Summary of Contents for 100 Series

Page 1: ...d Operation Guide ATMOR 100 Series Models 100 100V 101 101V 101P 101PV 102 102V 102P 102PV Instant hot water heater provides endless supply of hot water while significantly conserving energy and water www atmor net P N 000000 Reset Pump ...

Page 2: ...Hot Water on Demand 2 Dear Customer Thank you for purchasing Atmor instantaneous water heater High energy efficiency Slim design Flow controlled ...

Page 3: ...y or mental capabilities or lack of experience and knowledge unless they have been Using Double Pole ELSD For Phase and neutral Optional Single Pole ELSD Technical data For technical characterizes please refer to the appliance Data sticker Without pump With pump Model 1 9 kg 2 3 kg Weight 381 H 215 W 77 D mm Dimensions WARNING Earth Led Blue indicate the product properly grounded to protect from e...

Page 4: ...r It is recommended the top of the portion with the top of the heater Remove the terminal cover from the mounting terminal and screw the mounting to position Close the cover Insert the shower holder and soap Tray Close the cover 1 For the correct size of wire conductor corresponding to different electrical loading please refer to table 1 2 The built in ELSD will automatic cut off the power supply ...

Page 5: ...the stop valve 1 2 BSP 3 Connect the PVC hose and hand shower to the outlet of the heater be sure to put in the rubber washer 4 Hook the hand shower to the slider Rail Holder and adjust to your ideal position THE WATER INLET AND OUTLET MUST BE INSTALLED CORRECTLY OTHERWISE THE HEATER CAN NOT FUNCTION DO NOT USE PLUMBING CEMENT ON CONNECTION IF NECESSARY USE ONLY THREAD OR SEALING TAPE Turn on the ...

Page 6: ...an only from rear 3 Connect the cable to terminal block and fully tighten them insure no cable insulation is trapped under the screws as follow fig 5 BROWN or RED FOR LIVE L BLUE or BLACK for NEUTRAL N GREEN or Green Yellow for EARTH The cable clamp must be used to secure the cable fig 6 4 Check the wiring connection is tightens and correct then close the front cover When close back the front cove...

Page 7: ... high In this case you can adjust the water inflow in order to get the desired showering temperature 5 Check the Built in ELSD as follow Press the TEST button B the unit should trip and cut off the power supply All leds lamps should light off 6 Press the RESET button C the unit should resume normal function Green LED lamp should light on If the above mentioned procedures prevail the ELSD is functi...

Page 8: ... filter by turn it anti clockwise and flush it with water to remove any trapped Sediments Fitting and cleaning the Shower head Warning Metallic chromed hose and conductive control valve shall not be used Apply for products installed in Malaysia only Fit the two end brackets to the Rod Place the brackets with rod onto the wall and mark the position on the two screw holes Fit the end brackets holder...

Page 9: ...3 9 22 9 4 6mm2 6 5kW 29 5 28 2 27 0 4 0 6 0mm2 Wattage Amperage AMPs Cable Size mm2 1Ø 220V 1Ø 230V 1Ø 240V 7 5kW 34 1 32 6 31 3 4 0 6 0mm2 8 5kW 38 6 37 0 35 4 6 0 10 0mm2 9 5kW 43 2 41 3 39 6 6 0 10 0mm2 3Ø 220V 3Ø 230V 3Ø 240V 8 5kW 12 9 12 3 11 8 2 52 9 5kW 14 4 13 7 13 2 2 52 Table 1 Electrical Loading Table Wiring Diagram With Pump Power Pump 2P ELSD Control PCBA Power Pump SV 2P ELSD Contr...

Page 10: ...Hot Water on Demand 10 Wiring Diagram Without Pump Electrical connection ...

Page 11: ...Hot Water on Demand 11 Part List Terminal Block PCBA DP ELSD Optional SP ELSD PUMP Model Cover ELSD Cover Cover SP Tank Assy Main PCBA Control Pump Flow Switch Assy Inlet Outlet Reset Pump Reset Reset ...

Page 12: ...terruption of mains electrical supply ELSD trip possible earth leakage Check incoming power supply MCB switches and supply cabling Check earth leakage and reset ELSD If problem persists call your local authorised distributor for assistance Water ceases to flow Blockage of spray head twisted or blocked flexible shower hose No water supply Clean or replace sprayheed check for free passage of water t...

Reviews: