![Atmel XMEGA B User Manual Download Page 160](http://html1.mh-extra.com/html/atmel/xmega-b/xmega-b_user-manual_3003285160.webp)
160
XMEGA B [DATASHEET]
8291B–AVR–01/2013
13.7.4 32-bit Input Capture
Two timer/counters can be used together to enable true 32-bit input capture. In a typical 32-bit input capture setup, the
overflow event of the least-significant timer is connected via the event system and used as the clock input for the most-
significant timer.
The most-significant timer will be updated one peripheral clock period after an overflow occurs for the least-significant
timer. To compensate for this, the capture event for the most-significant timer must be equally delayed by setting the
event delay bit for this timer.
13.7.5 Capture Overflow
The timer/counter can detect buffer overflow of the input capture channels. When both the buffer valid flag and the
capture interrupt flag are set and a new capture event is detected, there is nowhere to store the new timestamp. If a
buffer overflow is detected, the new value is rejected, the error interrupt flag is set, and the optional interrupt is
generated.
13.8
Compare Channel
Each compare channel continuously compares the counter value (CNT) with the CCx register. If CNT equals CCx, the
comparator signals a match. The match will set the CC channel's interrupt flag at the next timer clock cycle, and the
event and optional interrupt are generated.
The compare buffer register provides double buffer capability equivalent to that for the period buffer. The double
buffering synchronizes the update of the CCx register with the buffer value to either the TOP or BOTTOM of the counting
sequence according to the UPDATE condition. The synchronization prevents the occurrence of odd-length, non-
symmetrical pulses for glitch-free output.
13.8.1 Waveform Generation
The compare channels can be used for waveform generation on the corresponding port pins. To make the waveform
visible on the connected port pin, the following requirements must be fulfilled:
1.
A waveform generation mode must be selected.
2.
Event actions must be disabled.
3.
The CC channels used must be enabled. This will override the corresponding port pin output register.
4.
The direction for the associated port pin must be set to output.
Inverted waveform output is achieved by setting the invert output bit for the port pin.
13.8.2 Frequency (FRQ) Waveform Generation
For frequency generation the period time (T) is controlled by the CCA register instead of PER. The waveform generation
(WG) output is toggled on each compare match between the CNT and CCA registers, as shown in
Summary of Contents for XMEGA B
Page 320: ...320 XMEGA B DATASHEET 8291B AVR 01 2013 Table 25 12 7 segments Character Table...
Page 321: ...321 XMEGA B DATASHEET 8291B AVR 01 2013 Table 25 13 14 segments Character Table...
Page 322: ...322 XMEGA B DATASHEET 8291B AVR 01 2013 Table 25 14 16 segments Character Table...
Page 412: ...412 XMEGA B DATASHEET 8291B AVR 01 2013...