ATAB542x-x-WB User Guide
..............................................................................................
ATMEL “Wireless BlackBird”Transceiver Demonstration Kit
Page 1: ...ATAB542x x WB User Guide ATMEL Wireless BlackBird Transceiver Demonstration Kit...
Page 2: ...rformance Characteristics 1 2 1 4 Kit Contents 1 2 Operating the Transceivers 2 1 2 1 Menu Guide Description 2 1 2 2 The Abridged Menu Guide 2 2 2 3 The Exhaustive Menu Guide 2 3 Appendix 3 1 3 1 Misc...
Page 3: ...of the box experience in mind Using the Quick Start Card included in the package an end user can within a matter of minutes have a demonstration running This User s Guide outlines the demo software m...
Page 4: ...te up to 20 Kbit s FSK and 10 Kbit s ASK Frequency Channels Multi channel operation over 2 5 MHz with 800 Hz resolution Temperature Range 40C to 85C Power Output 0 to 10 dBm switchable Supply Current...
Page 5: ...Introduction ATAB542x x WB User Guide 1 3 5219A WIRE 04 07 Figure 1 1 Wireless BlackBird Transceiver Figure 1 2 Wireless BlackBird Demonstration Kit...
Page 6: ...tion is not intuitively clear from simply the outline material alone The following are comments important to understanding these guides and navigating the Demo software menu 1 anything that appears on...
Page 7: ...ggling between MARK and SPACE FSK mode RSSI indicates received signal strength PKT TX transmits packet data PKT RX receives packet data S LINK serial link mode permits two PCs to communicate over an R...
Page 8: ...the screen The AVR logo and the device part number 542x are also displayed At this point P displays VERSION X XX the current version of the demo software P L R U D goes to power up display ATMEL SMAR...
Page 9: ...accesses menu items L goes to DIAGNOSTICS U D scrolls thru menu MARK SPACE CH x sets radio channel 0 to 9 P sets channel and goes to FSK L goes to FSK U increments channel D decrements channel FSK set...
Page 10: ...ges data rate 1 5 10 kbps for ASK 1 5 10 20 40 kbps for FSK RSSI number vertical bar graph shows a number and bar graph to indicate relative signal strength P L R U D goes to RSSI main menu 2 3 1 5 PK...
Page 11: ...thru menu MARK SPACE CH x sets radio channel 0 to 9 P sets channel and goes to FSK L goes to FSK U increments channel D decrements channel FSK sets transmitter to ASK or FSK P sets mode and goes to x...
Page 12: ...l link mode off SL OFF and returns to S LINK after momentary pause HOW TO EXECUTE THE S LINK FEATURE Connect the BlackBird s 3 pin UART header to a PC with a suitably modified serial RS232 cable NOTE...
Page 13: ...s signal strength received from the MASTER s transmitter as reported from the REMOTE L goes to LINK QUALITY R momentary hold changes display information MLINKxx XXXX etc U resets counter to 0000 HOW T...
Page 14: ...The MASTER cycles through 3 screens 1 M TEMP with AVR logo and antenna icon blinking and a thermometer icon 2 LOCAL the measured temperature at the MASTER and the thermometer icon 3 REMOTE the reporte...
Page 15: ...o S ADDR x L goes to S ADDR x U D toggles between SINGLE SENSOR and MULTI SENSOR S ADDR x sets the number of REMOTE sensors to poll P sets number and puts radio into MASTER mode L puts radio into MAST...
Page 16: ...d a valid return packet from the REMOTE Conversely indicates the data on that channel was not valid During this mode the REMOTE displays a 4 digit number if it receives at least one good packet of the...
Page 17: ...ts radio to channel 0 thru 9 P sets channel and goes to CH x AVR logo antenna and 4 digit number L goes to SYSTEM SET UP U D changes channel number CH x AVR logo antenna and 4 digit number initates tr...
Page 18: ...day number P sets selected value and goes to YEAR L goes to YEAR U D select day number 1 thru 31 YEAR sets year P sets selected value and goes to DAYOFWK L goes to DAYOFWK U D select year DAYOFWK sets...
Page 19: ...D and turns all segements on sequentially P again L R U D goes to SYSTEM SET UP 2 3 6 7 A D TST Shows that the A D converter works P accesses menu items L goes to SYSTEM SET UP U D scrolls through men...
Page 20: ...SETUP 2 3 6 9 TIME Displays day date time information P displays information L goes to SYSTEM SET UP U D scrolls through menu PWR DWN CHANNEL ADJUST P L R U D goes to SYSTEM SETUP 2 3 6 10 RF MODULE S...
Page 21: ...s pre set data for 433MHz P selects 433MHz data is loaded and then goes to SYSTEM SET UP L goes to SYSTEM SET UP U D scrolls through menu 5423 315MHZ 5425 345MHZ 5428 868MHZ selects pre set data for 8...
Page 22: ...lackBird with the executable software the FUSEs must be correctly set Here are the FUSEs which need to be checked in text and with snap shots of the pop up from AVR Studio brown out detection 1 8v JTA...
Page 23: ...cumentation To facilitate understanding the source code it is recommended that DOXYGEN soft ware http www doxygen com be used to generate documentation A file called Doxyfile is on the CD in the softw...
Page 24: ...1 408 441 0311 Fax 1 408 487 2600 Regional Headquarters Europe Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH 1705 Fribourg Switzerland Tel 41 26 426 5555 Fax 41 26 426 5500 Asia Room 1219 China...
Page 25: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Microchip ATAB5429 9 WB ATAB5423 3 WB ATAB5425 3 WB...