The Active Thermal Management Dual-cool is a self-contained ventilating system designed to 
cool audio-video installations in closets or cabinets, whether the equipment is on shelves or in 
racks.   
 
 

Rack-mounted systems 
 

To save valuable space on the front rails of the rack, Dual-cool can be mounted to the rack’s rear 
rails. It will protrude into the rack only 7”, allowing it to be located behind equipment that does 
not extend the full depth of the rack. It should be located near the top of the rack so that heat 
sources are below it.   

 

 
Shelf-mounted systems 
 

Fasten the (optional) wall mount bracket securely 12” to 18”  above the top shelf. The mounting 
holes are spaced 16” apart; fasten it securely into wall studs. Using the screws provide, fasten the 
Dual-cool to the bracket as shown.

 

 

 
 

All installations 
 

Connect the tubing supplied with the Dual-cool to its exhaust port and run it to the area where the 
hot air is to be exhausted. Use the backflow blocker (supplied) to hold the tubing against the wall 
or ceiling into which a 4” hole has been made for air flow as shown.   Attach the backflow 
blocker to the wall or ceiling first, making certain that the movable disc is positioned to prevent 
air from flowing towards the Dual-cool, then connect the tubing to the backflow blocker. 
 
After mounting the Dual-cool, connect the output lead from the power supply to the power input 
jack on the side of the Dual-cool’s chassis, and plug the power supply into an AC outlet.  

 
Plug the thermal probe into its connector on the Dual-cool’s chassis. If the probe is in an 
environment below about 90 degrees, the fans should not run. 