AT-OME-MS42
71
Solution Setup and Configuration Guide
Using IP
Instead of using a serial cable to send commands, this method uses an Ethernet cable to send commands from the
AT-OME-MS42 to the display device over IP network.
1.
Connect an Ethernet cable from the
LAN
port on the AT-OME-MS42, to the LAN port on the display.
DP
HDMI 3
HDMI 4
PWR
LINK
USB-C
HDBaseT OUT
AT-OME-MS42
OMEGA
TM
MULTI-FOMAT SWITCHER
IP MODE
DP
HDMI 3
HDMI 4
USB-C
HDMI OUT
HDMI IN
1
2
1
2
3
4
DP IN
USB-C IN
HDMI OUT
HDBaseT OUT
LAN
DC 24V
RESET
AUDIO OUT
USB HOST
RS-232
L
R
RX TX
+
+
USB
USB
USB HUB
to display
2.
Login to the web server. Refer to
Introduction to the Web Server (page 51)
.
3. Click
A/V Settings
in the menu bar.
4. Verify that the
Switching Mode
is set to
Mirrored
. Display control is
not
supported under
Matrix Mode
.
5. Click
Display
in the menu bar.
6.
Under
System Settings
, click the
Control Type
drop-down list and select
IP
.