AT-HDVS-210U-TX-WP
37
AVx1
Selects the desired input. The input number must be preceded with an “x” (e.g. x1 or x2). There is no space
between the first argument and the command. x1 = USB-C, x2 = HDMI.
Example
x2AVx1
Syntax
XAVx1
Parameter
Description
Range
X
Value
x1 ... x2
Feedback
x2AVx1
Commands
APwrOffTime
Set the time interval, in seconds, before the command to power-off the display is sent, once an A/V signal is no
longer detected. Use the
sta
argument to display the current setting.
Example
APwrOffTime 120
Syntax
APwrOffTime X
Parameter
Description
Range
X
Time interval
5 ... 3600, sta
Feedback
APwrOffTime 120
ASwOutTime
Sets the time interval, in seconds, before the unit automatically switches to another active input if no signal is
received from the current input. Use the
sta
argument to display the current setting.
Syntax
ASwOutTime X
Parameter
Description
Range
X
Time interval
3 ... 600, sta
Example
ASwOutTime 10
Feedback
ASwOutTime 10