Atmosphere
User Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
– 39 –
GPIO – High Priority Input
Setting up a High Priority GPIO to Play an Alert Message
In the UI, select the GPIO Toolbar then:
1. Select High Priority Input.
2. Enter a name for the function.
3. Select the type of activation control.
4. Select Wall Controllers to Lock & Alert, if desired.
5. Wall Controller Alerts will flash RED when active, if selected.
6. Select Action to Mute all Zones or Set all Zones to a source, Page mic or, in this example, play a message on all Zones.
Select Repeat Message Indefinitely, if desired.
7. Select the previously named and saved message file.
8. These faders allow setting the source level on the message input and zone outputs individually.
Note:
Default is -40dB.
9. Enable sets port “F” to activate with a contact closure input.
10. Status will light when triggered by CC on Port F.