Install Instructions

1516ALI & 1516BLI

Class A/B Loop Interface

9701 Taylorsville Rd. • Louisville, KY 40299  U.S.A.

Telephone: 502.267.7436 • Fax: 502.267.9070

1516ALI & 1516BLI

Class A/B Loop Interface

DOC1241B

Summary of Contents for 1516ALI

Page 1: ...e subject to change without notice Install Instructions 1516ALI 1516BLI Class A B Loop Interface 9701Taylorsville Rd Louisville KY 40299 U S A Telephone 502 267 7436 Fax 502 267 9070 1516ALI 1516BLI C...

Page 2: ...ville Rd Louisville KY 40299 U S A Telephone 502 267 7436 Fax 502 267 9070 Table of Contents Important Safety Instructions 3 Introduction 9 1516ALI Installation 11 Connecting Multiple Loops To One Amp...

Page 3: ...such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropp...

Page 4: ...exceed the power rating on the product when connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may...

Page 5: ...ns locales en vigueur WARNING If unit contains a lithium battery there is a danger of explosion Replace only with the same or equivalent type AVERTISSEMENT Si l unit contient une pile au lithium il y...

Page 6: ...pecific authorization adequate notices shall be posted to warn personnel of the potential hazard Avoid the use of flammable or toxic cleaning fluids and the use of carbon tetrachloride is prohibited M...

Page 7: ...servicing is started WARNING Discharging must be done carefully and judiciously First ascertain whether there is a built in bleeder network If so wait a minute or two for the capacitor to discharge th...

Page 8: ...should also be grounded separately by connection to a grounding bus or ground rod with a sufficiently large conductor to handle the current expected if the secondary source is accidentally shorted to...

Page 9: ...this represents 16 amplifier channels but it is possible to wire one amplifier channel to drive more than one speaker loop if that is how the facility wiring is arranged and the load presented by the...

Page 10: ...nnel loop This reflects what is also reported via the network 4 Fault Disable Jumpers One jumper per channel loop Placing a jumper on the pins disables fault reporting for this channel loop These shou...

Page 11: ...erve it in making the speaker loop connections before applying power to the amplifiers connected to the 1516ALI It is important that a speaker loop strictly observes polarity all along its path so tha...

Page 12: ...ations are subject to change without notice Install Instructions 1516ALI 1516BLI Class A B Loop Interface 9701Taylorsville Rd Louisville KY 40299 U S A Telephone 502 267 7436 Fax 502 267 9070 Figure 3...

Page 13: ...t load each on a 200 Watt amplifier channel This is done simply by daisy chaining the amplifier input wiring on the Amp In connectors of the 1516ALI as shown in the figure below Install Bypass Jumpers...

Page 14: ...on a compatible 10 x y z network in order to access the device at this address This may require one to temporarily add a compatible network setting on their laptop or desktop computer used to access t...

Page 15: ...DHCP dynamic addressing via the checkbox provided This is also where one can optionally build in an address to always report faults to e g a controller The Password edit box is where one can change th...

Page 16: ...pervised Device that can pass fault information via IEDnet This is done by adding a device of this type via the following steps Go to the Configuration tab page Select the Devices section Click on the...

Page 17: ...t of the device description followed by the fault numbers 40 x In the example both loops 15 and 16 are faulted for the newly added frame The fault descriptions can be made more meaningful by adding de...

Page 18: ...by sending the command via HTTP from a browser followed by a Reboot command The form of these commands are http w x y z cmd FactoryReset A55A http w x y z cmd Reboot A55A Where w x y z is the current...

Page 19: ...undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reaso...

Page 20: ...set forth below When products returned to AtlasIED do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is inclu...

Reviews: