Atlas SWC-500 Installation & Operating Manual Download Page 8

 

 

Maintenance  

                                                   

Warranty 

Do not allow the sludge accumulation in the             
tank to exceed a 1

 depth. Otherwise, the 

sludge build-up could damage the heating 
element(s) and pump. Depending on the   
application, some businesses have to clean 
out the sludge weekly, while others can go 
months before cleaning out the tank. Since 
you can’t see the sludge, clean out the tank 
within the first week of operation and 
develop an appropriate clean out schedule. 
The following procedure should be followed 
for sludge removal: 
 
     

 Disconnect all power to the machine 

          or make sure all breakers are in the   
          off position. 
     

 Remove the wash rack and filter 

     basket from the machine. 
     

 Using the drain, remove solution from 

          the tank. You can save the solution   
     for reuse. 
     

 Scrape out the sludge through the 

     filter basket opening being careful to 
     not hit the heating element. 
     

 Close the drain and install the filter 

     Basket and wash rack. 
     

 Fill tank with solution to proper level. 

 
If spray nozzles become clogged you may 
need to flush the spray tubes. Remove all   
pipe caps and bottom spray nozzles and run 
a maximum of 60 second wash cycle. 
 
 
 
 
 
 
 
Follow daily and monthly maintenance 
guidelines included in this manual. 
 
 
 
 
 
 
 
 
 
 

       
 

Limited Warranty 

 
This warranty covers any defects in 
manufacturing on your spray wash cabinet. 
 
This warranty lasts one (1) year from the date 
of purchase. Coverage terminates if you sell or 
otherwise transfer the spray wash cabinet 
during the period of the warranty.   
 
Rust, or any problem that is caused by abuse, 
misuse, or an act of God is not covered in this 
warranty. The manufacturer should not be 
liable in either tort or contract for any loss or 
damage, direct, indirect, special, 
consequential, or incidental, arising out of the 
use or inability to use this product. Some states 
or provinces do not allow the exclusion or 
limitation of incidental or consequential 
damages, so the above limitations may not 
apply to you. 

Summary of Contents for SWC-500

Page 1: ...I O N O P E R A T I O N MA N U A L A t l a s A u t o m o t i v e E q u i p m e n t w w w a t l a s a u t o e q u i p m e n t c o m 8 6 6 8 9 8 2 6 0 4 A t l a s S W C 5 0 0 S W C 7 5 0 S p r a y W a...

Page 2: ...e 8 Warranty 8 Maintenance Checklist 9 Troubleshooting 10 Safety is a critical factor in the design of spray wash cabinets The best program starts with a safety conscious operator The information high...

Page 3: ...Skimmer Cycle Timer 0 15Minutes 0 15Minutes Tank Capacity 50Gallons 53Gallons Stainless Steel Water Pump Standard Standard Turntable Friction Drive System Standard Standard Turntable Sprocket Drive Sy...

Page 4: ...l Skimmer Cycle Timer 0 15Minutes 0 15Minutes Tank Capacity 50Gallons 53Gallons Stainless Steel Water Pump Standard Standard Turntable Friction Drive System Standard Standard Turntable Sprocket Drive...

Page 5: ...r electrician install all suitable wiring and breaker disconnect box necessary Do not modify power cord installed on the unit Once power is installed have your electrician check motors for proper rota...

Page 6: ...ibility to perform any metallurgical tests on position Place parts on the wash rack making sure parts are placed to allow rotation of the wash rack Small parts can be placed in wash baskets provided w...

Page 7: ...electrical power to the most concerned about are corrosivity and machine Ep toxicity Ask your detergent supplier is 7 Turn the heater breaker to the on the PH of your solution is greater than 12 5 po...

Page 8: ...drain and install the filter Basket and wash rack Fill tank with solution to proper level If spray nozzles become clogged you may need to flush the spray tubes Remove all pipe caps and bottom spray n...

Page 9: ...sure all components are in good Clean up any spilled solution in operating condition surrounding area Inspect all electrical wiring Clean out removable filter basket Inspect pump for leaks Adjust dete...

Page 10: ...st thermostat Replace heating element Replace thermostat Repair and insulate connections Poor cleaning Incorrect detergent Low detergent concentration Hard water Clogged nozzles Solution is too dirty...

Page 11: ...11...

Reviews: