Atlas GUARDIAN PRO MLGS180B Manual Download Page 3

-3-

598-1096-01

Motion

Least Sensitive

Most Sensitive

Sensor

Motion

The sensor is less sensitive to motion directly
towards it, most sensitive to motion across its field
of view.

Maximum Range

Maximum

Coverage Angle

8 ft.

(2.4m)

70 ft.

(21m)

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE:

Sensor has a 1 

1

/

2

  minute calibration

period before it will detect motion. When
first turned on, wait 1 

1

/

2

 minutes.

RANGE

10 5 1 TEST

ON-TIME

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such

as heating vents and air conditioners. These
heat sources could cause false triggering.

• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting

light may trigger the shut-off feature. Do not point
other lights at the sensor.

MIN

MAX

180

°

Loosen the clamp screw in
the sensor ball joint and
gently rotate the sensor.

Walk through the cover-
age area noting where you
are when the lights turn on
(also, the LED will flash
several times when motion
is detected). Move the sen-
sor head up, down, or side-
ways to change the cover-
age area. Keep the sen-
sor at least 1" (2.5 cm)
away from the lamps.

Adjust the RANGE as
needed. RANGE set too
high may increase false
triggering.

Secure the sensor head
by tightening the clamp screw.
 Do not over-
tighten the screw.

Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Warning - Risk of fire. Do not aim the lamps at
a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . . .  Up to 70 ft. (21 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . . .  Up to 180

°

Electrical Load . . . . . . . .  Up  to  500  Watt  (4.2A)  Maxi-

mum Incandescent [Up to 250
Watt maximum each lamp
holder.]

Power Requirements . . .  120 VAC, 60 Hz
Operating Modes . . . . . .  TEST,  AUTO  and  MANUAL

MODE

Time Delay . . . . . . . . . .  1 , 5, 10 minutes
Range . . . . . . . . . . . . . .  Adjustable

Atlas Lighting Products, Inc. reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.

Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.