 9

Specifications are subject to change without notice

ECS-3

5. 

Pull Out Light Dimmer Switch – The Pull Out Light can be turned “On” or “Off” by this 

switch. There are also two brightness settings. 

6. 

AC Mains Function Display

 

7. 

AC Mains Voltage Display – This display will illuminate when the AC Mains power 

cord is 

plugged into an AC source. 

Note: the display has a 1.5% tolerance.

 

8. 

Sequence Indicator – There are three green LED active sequence outlet indicators 
labeled “SEQ 1”, “SEQ 2” and “SEQ 3”. Their sequence timing is set for 3 seconds between 
Sequence 1-2 & 2-3 while in “On” mode, and Sequence 3-2 & 2-1 during “Off” mode. When 
the LED is illuminated, the corresponding AC outlet on the rear of the chassis will be active or 
“Live”. Turned “On”, the order the trigger sequence is “SEQ 1, SEQ 2, SEQ 3”. Turned “Off”, it 
is “SEQ 3, SEQ 2, SEQ 1”.

9. 

AC Mains Wiring Polarity Fault Indicator – The Red LED will illuminate if the AC mains 

Power Cord is plugged into an AC Mains outlet that is wired incorrectly, such as when the AC 
Hot and the AC Neutral are wired backwards.

10. 

AC Mains Breaker Indicator – This Red LED will illuminate if the maximum unit current draw 

is exceeded. The breaker rating is 15A, but will handle higher peaks for a short period of time. 

The LED will illuminate until the AC Mains Breaker is reset.

11. 

AC Fault Indicator – Although the Dual Clamping Suppression (DCS) circuit virtually assures 

protection from most transient voltage spikes and surges. Nature has a way of occasionally 
creating electrical forces that are beyond the capabilities of any device to absorb without 
some degree of damage. In the rare instance that this occurs and the DCS circuit has been

6

12

11

10

9

8

7

Summary of Contents for ECS-3

Page 1: ...9 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 1 Specifications are subject t...

Page 2: ...Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 2 Specifications are subject to change without notice ECS 3 Table of Contents Safety Inst...

Page 3: ...y with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip ove...

Page 4: ...uct air flow to prevent the unit s internal temperature rise To prevent electric shock do not remove the device cover as there are high voltage components inside Refer all servicing to Atlas Sound Sho...

Page 5: ...onnected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be sure the installation of the product is stable avoid slanted surfaces as the product may fal...

Page 6: ...ers or wireless products EMI filters are incorporated to reduce noise from Electromagnetic Interference EMI from such items as electric motors switching power supplies and lightning The benefit of the...

Page 7: ...outlets off until it is manually reset The ECS 3 offers sequenced power management control along with noise filtering and spike surge protection making it the most compact effective power management...

Page 8: ...cations the ECS 3 can be used Restaurants Houses of Worship Schools Home Theaters Office Buildings Sports Bars Front Panel Features 1 Unswitched AC Outlet The two 120VAC outlets are always live when t...

Page 9: ...he LED is illuminated the corresponding AC outlet on the rear of the chassis will be active or Live Turned On the order the trigger sequence is SEQ 1 SEQ 2 SEQ 3 Turned Off it is SEQ 3 SEQ 2 SEQ 1 9 A...

Page 10: ...ctrician Low AC Line Mains The Abnormal voltage LED will flash between 101VAC 107VAC indicating possible damage may occur to equipment due to low AC Mains voltage The ECS 3 outlets will remain active...

Page 11: ...o AC outlets are Live when the Sequence 2 section is activated These outlets are recommended for Analog and Digital type products such as Audio Receivers Tape Decks Mixers or Video Equipment These out...

Page 12: ...AC Outlets The Unswitched Outlets are protected by the surge protection circuitry but will not be shut off by the EVS circuit 8 External Voltage Sequence Trigger The ECS 3 can be activated remotely b...

Page 13: ...an be placed on a shelf or rack mounted in a standard 19 width rack Placement within a rack is not critical but the rack should be within 6 of dedicated 15A AC outlet Always make sure the 15A outlet i...

Page 14: ...equence Note It is important to have all equipment that was connected to that AC Mains Line to be inspected for proper operation If the problem persists contact your local power company for the cause...

Page 15: ...tion 1 3 outlets Sequence Section 2 2 Outlets Sequence Section 3 1 outlet Unswitched 1 Outlet External Switch Activation Trigger Momentary contacts 2 position Euro Phoenix type connector External Volt...

Page 16: ...Max Spike Clamping Resp Time 1 nanosecond Spike Clamping Voltage 100A 1250Vp for 20 s Maximum surge current 6 500A Energy Rating 2ms 2000 Joules Noise Attenuation EMI RFI Seq Section 1 2 10dB 10 kHz...

Page 17: ...NNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 17 Specificatio...

Page 18: ...NNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 18 Specificatio...

Page 19: ...NNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 19 Specificatio...

Page 20: ...ower altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must...

Reviews: