ECS-3
OWNER’S MANUAL
Applications
The ECS-3 was designed to be flexible with features that allow it to be used in a variety of
applications. The sequenced outputs allow the turning of equipment on and off in a particular order,
to eliminate an in rush of current and audible pops that often occur with non-sequenced power strips.
It also can be used solely for protection against lightning strikes or voltage surges. If fuzzy video or
frequent static pops occur, the AC power conditioning will eliminate or reduce those inconveniences.
The following are just a few examples of applications the ECS-3 can be used:
• Restaurants
• Houses of Worship
• Schools
• Home Theaters
• Office Buildings
• Sports Bars
Front Panel Features
1.
Unswitched AC Outlet – The two 120VAC outlets are always live when the ECS-3 power
cord is plugged into an AC mains power source and voltage is present. If voltage is present
at the outlets, it will be displayed on the AC Mains Meter.
Note: The AC mains power switch
or sequencer section does not affect the Unswitched AC Outlets.
The Unswitched Outlets are
protected by the surge protection circuitry, but will not be shut off by the EVS circuit.
2.
AC Mains Breaker – The 15A rated breaker will open if the combined draw of all AC outlets
exceeds 15A.
Note: The breakers are designed to exceed their rating for a short period of
time.
If the breaker is tripped, to reset you must first remove the load from the ECS-3 and
push the center button in on the breaker.
3.
System Activation Switch – To turn the ECS-3 on or off, press the momentary switch once.
4.
Pull Out Light – The LED light is designed to be pulled out when needed.