Atlas ECS-3 Owner'S Manual Download Page 3

OWNER’S MANUAL

AtlasSound.com

1601 JACK MCKAY BLVD.  •  ENNIS, TEXAS 75119  U.S.A.
TELEPHONE: (800) 876-3333  •  FAX (800) 765-3435

©2008 Atlas Sound LP. All rights reserved.
Atlas Sound is a trademark of Atlas Sound LP.  Printed in China. 

ATS003211 RevA 8/08   

 3

Specifications are subject to change without notice

ECS-3

Safety Instructions

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this device near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the  

manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other device 

(including amplifiers) that produce heat. 

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 

has two blades with one wider than the other. A grounding type plug has two blades and 
a third grounding prong. The wide blade or the third prong are provided for your safety. If 
the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet. 

10.  Protect the power cord from being walked on or pinched particularly at plugs, convenience 

receptacles, and the point where they exit from the device.

11.  Only use attachments/accessories specified by the manufacturer.
12.  Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold 

with the device. When a cart is used use caution when moving the cart/device combination to 
avoid injury from tip-over.  

13.  Unplug this device during lightning storms or when unused for long periods 

of time. 

14.  Refer all servicing to qualified service personnel. Servicing is required when the device 

has been damaged in any way, such as power-supply cord or plug is damaged, liquid has 
been spilled, or objects have fallen into the device, the device has been exposed to rain or 
moisture, does not operate normally, or has been dropped. 

15.  WARNING: To reduce the risk of fire or electric shock, this device should not be exposed to 

rain or moisture and objects filled with liquids, such as a vase, should not be placed on this 
device. 

PA Amplifier 

Model AA35 

Output Rated 35W 

Designed and Engineered  

by Atlas Sound 

Made In CHINA 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

ATTENTION

 RISQUE DE DECHARGE ELECTRIQUE

-NE PAS OUVRIR.

WARNING

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK

 DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION

´

The lightning flash with arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage “ within the 
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons. 

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the 
literature accompanying the product.  

Summary of Contents for ECS-3

Page 1: ...9 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 1 Specifications are subject t...

Page 2: ...Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 2 Specifications are subject to change without notice ECS 3 Table of Contents Safety Inst...

Page 3: ...y with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip ove...

Page 4: ...uct air flow to prevent the unit s internal temperature rise To prevent electric shock do not remove the device cover as there are high voltage components inside Refer all servicing to Atlas Sound Sho...

Page 5: ...onnected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be sure the installation of the product is stable avoid slanted surfaces as the product may fal...

Page 6: ...ers or wireless products EMI filters are incorporated to reduce noise from Electromagnetic Interference EMI from such items as electric motors switching power supplies and lightning The benefit of the...

Page 7: ...outlets off until it is manually reset The ECS 3 offers sequenced power management control along with noise filtering and spike surge protection making it the most compact effective power management...

Page 8: ...cations the ECS 3 can be used Restaurants Houses of Worship Schools Home Theaters Office Buildings Sports Bars Front Panel Features 1 Unswitched AC Outlet The two 120VAC outlets are always live when t...

Page 9: ...he LED is illuminated the corresponding AC outlet on the rear of the chassis will be active or Live Turned On the order the trigger sequence is SEQ 1 SEQ 2 SEQ 3 Turned Off it is SEQ 3 SEQ 2 SEQ 1 9 A...

Page 10: ...ctrician Low AC Line Mains The Abnormal voltage LED will flash between 101VAC 107VAC indicating possible damage may occur to equipment due to low AC Mains voltage The ECS 3 outlets will remain active...

Page 11: ...o AC outlets are Live when the Sequence 2 section is activated These outlets are recommended for Analog and Digital type products such as Audio Receivers Tape Decks Mixers or Video Equipment These out...

Page 12: ...AC Outlets The Unswitched Outlets are protected by the surge protection circuitry but will not be shut off by the EVS circuit 8 External Voltage Sequence Trigger The ECS 3 can be activated remotely b...

Page 13: ...an be placed on a shelf or rack mounted in a standard 19 width rack Placement within a rack is not critical but the rack should be within 6 of dedicated 15A AC outlet Always make sure the 15A outlet i...

Page 14: ...equence Note It is important to have all equipment that was connected to that AC Mains Line to be inspected for proper operation If the problem persists contact your local power company for the cause...

Page 15: ...tion 1 3 outlets Sequence Section 2 2 Outlets Sequence Section 3 1 outlet Unswitched 1 Outlet External Switch Activation Trigger Momentary contacts 2 position Euro Phoenix type connector External Volt...

Page 16: ...Max Spike Clamping Resp Time 1 nanosecond Spike Clamping Voltage 100A 1250Vp for 20 s Maximum surge current 6 500A Energy Rating 2ms 2000 Joules Noise Attenuation EMI RFI Seq Section 1 2 10dB 10 kHz...

Page 17: ...NNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 17 Specificatio...

Page 18: ...NNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 18 Specificatio...

Page 19: ...NNIS TEXAS 75119 U S A TELEPHONE 800 876 3333 FAX 800 765 3435 2008 Atlas Sound LP All rights reserved Atlas Sound is a trademark of Atlas Sound LP Printed in China ATS003211 RevA 8 08 19 Specificatio...

Page 20: ...ower altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must...

Reviews: