PV Input data

DC voltage range(V)

MPP operating voltage range(V)

Max. power(W)

Number of MPPT

Inputs per MPPT

Nominal Output Current(A)

Max. Output Current(A)

AC Grid output data

Rated voltage(V)

Operating voltage range(V)

Operating frequency(Hz)

Operating frequency range(Hz)

Phase shift

Reactive power adjust range

THDI

UPS AC output data

Nominal output current(A)

Rated output power(VA)

Operating frequency(Hz)

THDV

Switching Time

Efficiency

Max. Efficiency @ PV to grid

Max. Efficiency @ battery to grid

Battery data

Type

Max. charge current(A)

Max. discharge current(A)

Nominal voltage(V)

Voltage range(V)

Integrated disconnect

Reverse polarity protection

DC switch rating for each MPPT

Output over-voltage protection varistor

General Data

Output over current protection

Ground fault monitoring

Grid monitoring

Pole sensitive leakage current Monitoring unit

RSD

Dimensions(mm)

Weight(kg)

12K 

50

50

@240V 12000/@208V 10400

Sync inrush curent(A)

Nominal power output(W)

Nominal output voltage(V)

Degree of protection

Max. usable input current(A)

Max. short circuit input current(A)

Start input voltage(V)

Startup voltage(V)

Full power MPPT voltage range(V)

DC nominal voltage(V) MPPT tracker

230-500

AFCI

Peak power(VA)

MPPT Efficiency

Cooling concept

Relative humidity

Altitude(m)

Noise emission(dB)

Internal consumption(W)

Topology

Display

Communication interface

Standard warranty

50

@240V 12000/@208V 10400

18000

250

250

25/15/15

34/17/17

100

140

100-600

120-500

360

3

2/1/1

180-270

240

 -0.8~+0.8 leading Adjustable

60

55-65

<3%

35

0.99@full load

[240][120/240][120/208]

<3%

<20

60

97.5% 

94%

99.9%

48

40-60

Lead-acid battery/Lithium battery

Yes

DC switch

Yes
Yes

Yes

Yes

Yes

Yes

YES

670*490*265mm(22.8*19.3*10.4inch)

50kg(96.8 Ibs)

NEMA4X / IP 65

FAN

YES

0-100%

<2000m

<50dB

<15W

Touch color screen

Transformer-less

5years

Rs485/ Wi-Fi/ CAN

2xPn, 0.5s

When the grid voltage exceeds V1, the output active power varies with the grid voltage.

Note: When setting the protection time, it needs to be converted into the number of cycles of the 

corresponding frequency;

6.2.10   Active power limit mode

V2

1.1*Un

Parameter name

Default Value

106%Vnom

V1

P1

Ppre-disturbance (for 
active power output at 
the time voltage exceeds 
V1 in p.u. of Prated)

Pmin (for Advanced 
Inverters that can only 
inject active power, 
Pmin should approach 0)

10S

Open Loop 

Response Time

P2

Disable 

Voltage-Active 

Power Mode

1.04*Vn

Minimum 

Adjustable Range

105%Vnom

0.5S

N/A

1.10*Vn

Maximum 

Adjustable Range

109%Vnom

60S

N/A

N/A

N/A

N/A

N/A

Parameter name

Default Value

100

Maximum Active Power(%)

Enable

Active power limit mode

Minimum 

Adjustable Range

0

N/A

Maximum 

Adjustable Range

100

N/A

6.3    Test parameter tolerances

Parameter

Units

Current

Volts

±

1%Urated

Amps

±

1%Urated

Watts

±

1%Urated

Power

Default Tolerance 

of Measurement

Reactive Power

Power Factor

Voltage

VA

Displacement 

power factor 

Hz

Frequency

Response Time

Time accuracy

Seconds

Total time

±

5%Srated

±

0.01

±

0.05

1

0.1%

Operating temperature range (

)

-25~60

℃,>

45

℃ 

Derating

Summary of Contents for ATL12KW2897-22

Page 1: ...Version EN UM 1 0 00 Atlas Energy Solutions 848 W 1440 N suite 120 Logan UT 84321 1 435 233 6115...

Page 2: ...CT Meter connection 3 6 4 13 Working with Generator 3 7 15 Generator system connection 3 7 1 15 Generator Startup and stop settings 3 7 2 17 Monitor System Setup 3 10 21 3 10 1 3 10 2 Wifi GPRS 4G WLA...

Page 3: ...can interconnected with the utility grid Avoid misoperation and Inappropriate Usage All the work of this product system design installation operation setting configuration and maintenance must be car...

Page 4: ...system B AC Coupling with existed solar system C On grid solar system without battery Support EPS even without battery D Off grid and back up applications E Single and three phase paralleling system...

Page 5: ...ing bracket then drill 4 holes of 8mm 5 16inch diameter and make sure the depth of the holes is deeper than 50mm 2inch Step3 Hang the inverter onto the wall mounting bracket and lock the inverter on t...

Page 6: ...CAN RS485 please check Chapter 3 5 2 for Pin definition please check Chapter 3 9 for Parallel connection e Parallel communication port f FAN1 2 3 g TEMP Connection for temperature sensor of lead acid...

Page 7: ...duit fittings are fastened reliably and seal the cable entry holes 3 5 Battery Connection 3 5 1 Battery power cable connection 2 3 0 4 0 AWG 85 100 mm 600V Cable Requirement 12K Step 2 Route the batte...

Page 8: ...y master and slave settings 1 The temperature sensor for lead acid battery is optional If you need it please contact distributor for purchasing For Li ion battery For Lead acid battery 2 There are thr...

Page 9: ...talled at the service entry point in or near the main service panel We standard supply 2 CT for one inverter The CT interface for 2 CTs connection is a RJ45 port we have made a RJ45 plug on those 2 CT...

Page 10: ...ter Service Disconnect Generator Inverter Disconnect Generator Disconnect Backup Panel Generator Connection Whole Home Backup PE N PE L1 L2 PE N L2 L1 PE N L2 L1 2 wire start CT 2 CT 1 When generator...

Page 11: ...kw h 10A Generator Start Conditions Generator Stop Conditions when battery voltage or SOC higher than Charge end Volt SOC settings value When grid is off the hybrid inverter will work as a power sourc...

Page 12: ...erent using scenarios Up to 10 units can be paralleled to reach a capacity of 120kW Wiring diagram is as below The manual bypass switch connect loads to EPS panel for default When inverters fail users...

Page 13: ...ur mobile phone to the BAxxxxxxxx wireless network where BAxxxxxxxx is the serial number of the WiFi dongle luxpower_5G luxpowertek luxpowertek_5g HF WIFI ChinaNet EWP ChinaNet wG49 CMCC BAKR luxpower...

Page 14: ...arallel cable communication Interface DRM Interface Meter INV485 4 Operation Guide 4 1 Operation Mode The inverter has different working mode to meet customers various demands the working modes are as...

Page 15: ...2 3 1 Import Power Example 4 1 3 AC Charge Mode Users can charge battery with grid power when electricity price is cheap and discharge battery power to supply load or export to the grid when electric...

Page 16: ...m of the screen you ll see all current and historical fault warning information on this page Alarm record M8 Rx fault Inconsistant Fault status Fault record Alarm status M3 Rx failure Model fault Rese...

Page 17: ...its CT ratio is either 1000 1 or 3000 1 and set it accordingly the battery brand in the Lithium brand drop down list Meter type Please select it according to the meter that s to be installed Offgrid...

Page 18: ...ntact Luxpower service or your inverter supplier 1 Check if the L1 L2 and N wires are connected correctly at inverter EPS output port 2 Disconnect the EPS breaker to see if fault remains If fault pers...

Page 19: ...n EPS port Restart inverter If fault still exists contact Luxpower service or your inverter supplier Check if meter communication cable is connected correctly on inverter and meter side RSD Active Off...

Page 20: ...llowing up the below diagram if there is problem with the fans Turn off the system and wait for more than 5 minutes before disassembling the machine c Loosen the screws and remove them d Remove the fa...

Page 21: ...an activation the Rule21 function Setting the value in the corresponding blank Before setting you can read the default value first and then set the parameter of the function that needs to be modified...

Page 22: ...mum Adjustable Range 61 0Hz 180s 180 50 0Hz 160ms 61 8Hz 160ms Maximum Adjustable Range 59 0Hz 66 0Hz 1000s 1000s 57 0Hz 1000s 66 0Hz 1000s 6 2 4 Specified Power factor SPF Parameter name Default Valu...

Page 23: ...Q2 Q3 Constant Reactive Power 44 of nameplate apparent power Parameter name Default Value Under excited Under excited Over excited Disable Constant Reactive Power Mode Minimum Adjustable Range Under e...

Page 24: ...208V 10400 18000 250 250 25 15 15 34 17 17 100 140 100 600 120 500 360 3 2 1 1 180 270 240 0 8 0 8 leading Adjustable 60 55 65 3 35 0 99 full load 240 120 240 120 208 3 20 60 97 5 94 99 9 48 40 60 Le...