Atlas ATL12KW2897-22 User Manual Download Page 19

33

34

Auto test failure

Auto test failed

Inverter fails to communicate with 
the meter

Bat Fault

Battery cannot charge or discharge

1. Check the battery communication cable for 
correct pinout on both inverter and battery end;

1. Check if the communication cable is connected 
correctly and in good condition.

Lcd com failure

LCD fails to communicate with M3 
microprocessor

Trip by gfci high

Trip by dci high

PV short circuit

Bat open

Bat volt low

GFCI module fault

Inverter detected high DC injection 
current on grid port

Battery is disconnected from 
inverter

Battery voltage too low

Inverter detected leakage current 
on AC side

Inverter detected short circuited 
PV input

GFCI module is abnormal

1. Check if each PV string is connected correctly;

Restart inverter. If fault still exists, contact 
Luxpower service or your inverter supplier.

Check if battery voltage exceeds 59.9V, battery 
voltage should be within inverter specification. 

Fwm mismatch

Fan stuck

Firmware version mismatch 
between the microprocessors

Cooling fan(s) are stuck

Bat volt high

Battery voltage too high

2. Restart inverter. If the fault persists, contact 
Luxpower service or your inverter supplier. 

Only applied to Italy model

PV arc fault is detected

AFCI high

Check each PV string for correct open circuit 
voltage and short circuit current. If the PV strings 
are in good condition, please clear the fault on 
inverter LCD.

Meter com failure

2.  Check if you have chosen an incorrect battery 
brand;

3.  Check if there is fault on battery's indicator. If 
there is fault, please contact your battery supplier.

Restart inverter. If fault still exists, contact 
Luxpower service or your inverter supplier.

1. Check if there is ground fault on grid and load side;

2. Restart inverter. If the fault remains, contact 
Luxpower service or your inverter supplier.

Restart inverter. If the fault remains, contact 
Luxpower service or your inverter supplier.

2. Restart inverter. If the fault remains, contact 
Luxpower service or your inverter supplier.

Check if battery voltage is under 40V, battery 
voltage should be within inverter specification.

Check battery breaker or battery fuse.

Meter reversed

Offgrid overvolt

Meter is connected reversely

EPS voltage is too high

Check if load power on inverter EPS port is within 
inverter specification.

Offgrid overload

Overload on EPS port

Restart inverter. If fault still exists, contact 
Luxpower service or your inverter supplier.

Check if meter communication cable is connected 
correctly on inverter and meter side. 

RSD Active

Offgrid dcv high

Rapid shutdown activated

High DC voltage component on 
EPS output when running off-grid

Restart inverter. If fault still exists, contact 
Luxpower service or your inverter supplier.

Check if the RSD switch is pressed.

2.  Alarm on the LCD

If the dot on the left of fault item is yellow, it means the fault is active. When it is grey, it means the fault is deactive

Offgrid dcv high

RSD Active

ReservedP

ReservedQ

PV short circuit

Bat volt high

Fwm mismatch

AFCI high

Trip by dci high

Offgrid overload

Meter reversed

Bat Fault

Trip by iso low

GFCI module fault

Bat volt low

Bat com failure

AFCI com failure

Trip by no AC

Trip by gfci high

Bat open

Offgrid overvolt

Meter com failure

Fan stuck

Trip by Vac abnormal

Auto test failure

Lcd com failure

B

reversed

at 

ReservedR

Alarm record

Fault status 

Fault record

Alarm status

Trip by Fac abnormal

Arc fault

Inverter fails to communicate with 
battery

AFCI com failure

Inverter fails to communicate with 
AFCI module

Check if communication cable is correct, and if you 
have chosen the correct battery brand on inverter 
LCD. If all is correct but this error persists, please 
contact Luxpower service or your inverter supplier.

Restart inverter, if the error persists, contact 
Luxpower service or your inverter supplier.

Meaning

Alarm

Troubleshooting

Bat com failure

Hard over curr

Neutral fault

PV short circuit

M8 Rx fault

Inconsistant

Temperature fault

Voltage between N and PE is 
greater than 30V

M8 microprocessor fails to 
receive data from DSP

Sampled grid voltage values of 
DSP and M8 microprocessor are 
inconsistent 

Hardware level over current 
protection triggered

Short circuit detected on PV input

Heat sink temperature too high

Restart inverter, if the error still exists, contact 
Luxpower service or your inverter supplier.

Check if the neutral wire is connected correctly.

Disconnect all PV strings from the inverter. If the 
error persists, contact Luxpower service or your 
inverter supplier.

Install the inverter in a place with good ventilation 
and having no direct sunlight. If the installation site 
is okay, please check if the NTC connector inside the 
inverter is loose.

Restart inverter, if the error still exists, contact 
Luxpower service or your inverter supplier.

Bus sample fault

Inverter detected DC bus voltage 
lower than PV input voltage

Summary of Contents for ATL12KW2897-22

Page 1: ...Version EN UM 1 0 00 Atlas Energy Solutions 848 W 1440 N suite 120 Logan UT 84321 1 435 233 6115...

Page 2: ...CT Meter connection 3 6 4 13 Working with Generator 3 7 15 Generator system connection 3 7 1 15 Generator Startup and stop settings 3 7 2 17 Monitor System Setup 3 10 21 3 10 1 3 10 2 Wifi GPRS 4G WLA...

Page 3: ...can interconnected with the utility grid Avoid misoperation and Inappropriate Usage All the work of this product system design installation operation setting configuration and maintenance must be car...

Page 4: ...system B AC Coupling with existed solar system C On grid solar system without battery Support EPS even without battery D Off grid and back up applications E Single and three phase paralleling system...

Page 5: ...ing bracket then drill 4 holes of 8mm 5 16inch diameter and make sure the depth of the holes is deeper than 50mm 2inch Step3 Hang the inverter onto the wall mounting bracket and lock the inverter on t...

Page 6: ...CAN RS485 please check Chapter 3 5 2 for Pin definition please check Chapter 3 9 for Parallel connection e Parallel communication port f FAN1 2 3 g TEMP Connection for temperature sensor of lead acid...

Page 7: ...duit fittings are fastened reliably and seal the cable entry holes 3 5 Battery Connection 3 5 1 Battery power cable connection 2 3 0 4 0 AWG 85 100 mm 600V Cable Requirement 12K Step 2 Route the batte...

Page 8: ...y master and slave settings 1 The temperature sensor for lead acid battery is optional If you need it please contact distributor for purchasing For Li ion battery For Lead acid battery 2 There are thr...

Page 9: ...talled at the service entry point in or near the main service panel We standard supply 2 CT for one inverter The CT interface for 2 CTs connection is a RJ45 port we have made a RJ45 plug on those 2 CT...

Page 10: ...ter Service Disconnect Generator Inverter Disconnect Generator Disconnect Backup Panel Generator Connection Whole Home Backup PE N PE L1 L2 PE N L2 L1 PE N L2 L1 2 wire start CT 2 CT 1 When generator...

Page 11: ...kw h 10A Generator Start Conditions Generator Stop Conditions when battery voltage or SOC higher than Charge end Volt SOC settings value When grid is off the hybrid inverter will work as a power sourc...

Page 12: ...erent using scenarios Up to 10 units can be paralleled to reach a capacity of 120kW Wiring diagram is as below The manual bypass switch connect loads to EPS panel for default When inverters fail users...

Page 13: ...ur mobile phone to the BAxxxxxxxx wireless network where BAxxxxxxxx is the serial number of the WiFi dongle luxpower_5G luxpowertek luxpowertek_5g HF WIFI ChinaNet EWP ChinaNet wG49 CMCC BAKR luxpower...

Page 14: ...arallel cable communication Interface DRM Interface Meter INV485 4 Operation Guide 4 1 Operation Mode The inverter has different working mode to meet customers various demands the working modes are as...

Page 15: ...2 3 1 Import Power Example 4 1 3 AC Charge Mode Users can charge battery with grid power when electricity price is cheap and discharge battery power to supply load or export to the grid when electric...

Page 16: ...m of the screen you ll see all current and historical fault warning information on this page Alarm record M8 Rx fault Inconsistant Fault status Fault record Alarm status M3 Rx failure Model fault Rese...

Page 17: ...its CT ratio is either 1000 1 or 3000 1 and set it accordingly the battery brand in the Lithium brand drop down list Meter type Please select it according to the meter that s to be installed Offgrid...

Page 18: ...ntact Luxpower service or your inverter supplier 1 Check if the L1 L2 and N wires are connected correctly at inverter EPS output port 2 Disconnect the EPS breaker to see if fault remains If fault pers...

Page 19: ...n EPS port Restart inverter If fault still exists contact Luxpower service or your inverter supplier Check if meter communication cable is connected correctly on inverter and meter side RSD Active Off...

Page 20: ...llowing up the below diagram if there is problem with the fans Turn off the system and wait for more than 5 minutes before disassembling the machine c Loosen the screws and remove them d Remove the fa...

Page 21: ...an activation the Rule21 function Setting the value in the corresponding blank Before setting you can read the default value first and then set the parameter of the function that needs to be modified...

Page 22: ...mum Adjustable Range 61 0Hz 180s 180 50 0Hz 160ms 61 8Hz 160ms Maximum Adjustable Range 59 0Hz 66 0Hz 1000s 1000s 57 0Hz 1000s 66 0Hz 1000s 6 2 4 Specified Power factor SPF Parameter name Default Valu...

Page 23: ...Q2 Q3 Constant Reactive Power 44 of nameplate apparent power Parameter name Default Value Under excited Under excited Over excited Disable Constant Reactive Power Mode Minimum Adjustable Range Under e...

Page 24: ...208V 10400 18000 250 250 25 15 15 34 17 17 100 140 100 600 120 500 360 3 2 1 1 180 270 240 0 8 0 8 leading Adjustable 60 55 65 3 35 0 99 full load 240 120 240 120 208 3 20 60 97 5 94 99 9 48 40 60 Le...

Reviews: