Installation
34
PVL14OF-EXT
7.15 Oil Filling And Bleeding
DO NOT run power unit with no oil. Damage to pump can occur.
If motor gets hot or sounds peculiar, stop immediately and
recheck the electric connection.
• Use the hydraulic fl uid recommended in the chapter 5.5.
• Remove the vented cap on the oil tank and pour oil in the tank about 17
liters.
• Cycle the lift up and down several times to bleed the hydraulic system until
the lift is lowered smoothly. To lower the lift, latches must be released by
depressing the air valve.
• Fill the more fl uid if necessary till the tank is full.
7.16 Final
Installation
7.16.1 Runway Leveling Adjustment
Runways must be leveled side to side, front to rear. The
maximum tolerance cannot be over 1.5mm.
• Raise the lift off all latches until the cables are supporting the lift and check
that all cables are adjusted in the same tension.
• Verify if both the runways are leveled horizontally by means of a water
gauge or a leveling instrument. If not, readjust cables.
7.16.2 Locking Position Adjustment
All latches must be engaging uniformly before any attempt is
made to work on or near the vehicle.
• Raise the lift from bottom to top and verify if all latches can be clicked into
the locking positions.
• Lower the lift to the topmost latch position to verify if four latches are
engaging uniformly. If not, readjust cables.