Atmosphere
User Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
– 26 –
Signal Generator Input
The Signal Generator Input provides a way to test, setup, and troubleshoot zones with a consistent audio source. A sine wave with frequency setting is
a tone and useful in calibration throughout the system. White noise is a random signal containing equal energy per frequency, giving it a constant power
spectral density. Pink noise has equal energy per octave. Octave bands are how humans hear so it is useful for setting up music levels in zones.
1. Signal Type – select sine wave, white noise, pink noise
2. Enter the frequency for sine waves in Hz
3. Set input level
*The Signal Generator can be assigned as a source on zone outputs only.
Zone Outputs
The Outputs page displays the AZM4 or AZM8, 4 or 8 zone outputs.
1. Click on the Outputs toolbar to open the output zones page.
2. Each output zone can be named here and will populate all other respective outputs where displayed, system wide.
3. Input Source Select – select from the available dropdown list.
4. This is the input priority signal activity indicator.
5. Output Level adjust – move fader or enter dB desired output level in window. When signal is present, fader animates as a peak meter and shows:
Blue-signal activity, Red-clipping.
6. Limiter Activity indicator, Yellow - limiting, Gray - no limiting
7. Mute – select to mute output channel
8. Link to settings navigates to the following pages: