   WARNING - When The Device Is In Use

  

 

•  WARNING: The terminals marked with symbol of      may be of sufficient magnitude to constitute a risk of electric shock. The external wiring  
 

connected to the terminals requires installation by an instructed person or the used of ready-made leads or cords.

•  WARNING: The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on  
 apparatus. 
•  WARNING: The mains plug is used as disconnect device, the disconnect device shall remain readily operable.
•  To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to AtlasIED. 
•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and  
 

contact AtlasIED. Do not to attempt to continue operation with the product as this may cause fire or electric shock:

 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

• 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in electric shock or  

 fire.
• 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric shock may result.

• 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

• 

Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result. 

• 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used. 

• 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy  

 

objects on the power cord, including the product itself, doing so may result in fire or electrical shock. 

• 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic disaster may  

 result. 
• 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.

 

   CAUTION - When Installing The Product

 
•   Plugging in or unplugging the power cord with wet hands may result in electric shock. 
•  Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
•  When unplugging the cord from the wall, grasp the plug, NOT the cord. 
•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or steam are  
 

present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

/

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

 

   CAUTION - When The Product Is In Use

 
•  Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In addition, the product  
 

itself may fall and cause injury and property damage. 

•  Contact AtlasIED for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat buildup and fire. 
•  Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or inside the wall  
 outlet. 
•  When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

Summary of Contents for ASP-MG24

Page 1: ...1 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A ASP MG24 ASP MG24TDB Signal Processor Masking Generator 2 Input x 4 Output...

Page 2: ...TEXAS 75119 U S A Table of Contents Important Safety Instructions 3 Introduction 5 Key Features 5 Front Panel Description 6 Rear Panel Description 7 Getting to Know the Software 8 Mic Line Input 9 Ma...

Page 3: ...our electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 14 Unplug this device during lightning storms or when unused for long periods of time 15 Ref...

Page 4: ...connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not mod...

Page 5: ...ections 31 band EQ white pink noise auto ramp routing mixing and compressor limiters The ASP MG24 can be controlled or configured in real time with the intuitive PC GUI accessed via the RS 232 or USB...

Page 6: ...2 Level LED Indicators 5 LEDs per channel indicate the status of the signal level Signal 12dB 6dB 3dB Over Limit A dual use LED indicates maximum headroom and limiter threshold 3 RS232 Connector Stand...

Page 7: ...lying signal to the input set the analog gain switch to match the type of input being used The Line position gain is calibrated for 0dBu or unity gain within the DSP software The Mic position gain is...

Page 8: ...rsonal viewing preferences 3 After the software is loaded and the proper screen resolution is set open the software and follow the steps below Note It is not necessary to have the computer connected t...

Page 9: ...d is PRE input filters and compressor settings Gain For convenience both Mic Line inputs and the four masking generators levels are shown Controlling the gain can be accomplished by dragging the fader...

Page 10: ...second is the settings screen This screen controls Threshold Attack Release and Ratio Adjustment can be made using the up down arrows or by typing into the data viewing text box Threshold Limit thresh...

Page 11: ...tion Also use the screen curser up down arrows to find the three screens All 3 screens can be moved by clicking and holding the selected screen for personal viewing preferences Graphic Screen This scr...

Page 12: ...AS 75119 U S A Crossover Window The Crossover window allows the adjustment of filter type frequency and slope The Reset button will set all filters back to factory settings and only affects the settin...

Page 13: ...red turn on signal ramp time during power up The Time buttons allow adjustment of the amount of preset time needed The amount of steps is a formula of gain divided by time The ramp interval voltage ch...

Page 14: ...l Mute can be accomplished by clicking on the Mute button It will illuminate red indicating the channel is in Mute Masking EQ When clicking on the filter screen 3 sub viewing screens appear Note All 3...

Page 15: ...settings and only effects the settings in this screen There are 20 1 3 octave band filters available to adjust the measured masking signal A generous 15dB and 30dB boost and cut are offered in 0 25dB...

Page 16: ...to 0dB Controlling the mixed gain can be accomplished by dragging the fader using the up down buttons or typing in the number viewing text box Note The signal feeding into the mixer will not be effect...

Page 17: ...screens can be moved for personal viewing preferences Graphic Screen This screen will display all of the filter characteristics that are set Filter Window Each input has 8 adjustable filter selection...

Page 18: ...Delay Window The Delay window allows adjustment of the channel delay from 0ms to 200ms per output Controlling the mixed gain can be accomplished by using the up down buttons or by typing in number vi...

Page 19: ...ndicator screen showing the compressor limiter operation Screen 2 is the settings screen which controls Threshold Attack Release and Ratio Adjustment can be made using the up down arrows Threshold Lim...

Page 20: ...BLVD ENNIS TEXAS 75119 U S A Mute Channel Mute can be accomplished by clicking on the Mute tab and will illuminate red indicating the channel is in Mute Output Meter The bar graph meter illustrates t...

Page 21: ...and Export Master Reset All This button is the master reset button and will override all settings Note A confirmation widow will pop up File Open Program files can be recalled from the PC or Laptop It...

Page 22: ...in non volatile memory that can store up 14 different program setups A program can be recalled from the device When doing so only one program can be open on the desktop GUI Once recalled the program...

Page 23: ...rs and sound masking setups Meter Real time meters for all inputs outputs Scaled in V RMS dBu and dBV These are helpful when troubleshooting Scheduler The ASP MG24TDB contains a programmable clock and...

Page 24: ...ck the Initial Ramp Commission button 2 Click the Start Date drop down menu and select the start date 3 Set the start level for the masking signal typically 10dB down from the target level 4 Click the...

Page 25: ...allow selection of any of the 4 masking channels and 2 inputs to be configured to a schedule as well as choosing the day of the week to program To reduce data entry time create a schedule for one day...

Page 26: ...uts 4 Outputs 3 pin Balanced Phoenix DC Power Receptacle 5 Pin DIN Connector Audio Control Parameters Gain 40dB to 15dB in 0 25dB Steps Polarity Delay Up to 200ms per I O Parametric Filters 8 per I O...

Page 27: ...ters High Performance 24 bit Propagation Delay 3ms Electrical Specifications General Input Impedance Line 10k Ohms Mic Output Impedance 50 Ohms Maximum Input Output Level 20dBu Frequency Response 20Hz...

Page 28: ...T ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Dimensional Drawings Power Data ASP MG24 2x4 Signal Processor Masking Generator 1 2 Over Limit 3dB 6dB 12dB Signal Inputs RS232 USB 1 2 3 Ou...

Page 29: ...29 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Page 30: ...30 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Page 31: ...31 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Page 32: ...ed or operated in excess of rated power altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this...

Reviews: