background image

– 3 –

ASP-MG24

Owner’s Manual

AtlasIED.com

TELEPHONE: (800) 876-3333

[email protected]

1601 JACK MCKAY BLVD. 

ENNIS, TEXAS 75119 U.S.A.

Important Safety Instructions

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this device near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other devices that produce heat. 
9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A  

 

 

grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided  

 

 

plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the  

 

 device.
11.  Only use attachments / accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used, use caution  

 

 

when moving the cart / device combination to avoid injury from tip-over. 

13. This product is equipped with a three-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type    
 

power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do  

 

not defeat the safety purpose of the grounding-type plug.

14. Unplug this device during lightning storms or when unused for long periods of time. 
15. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as power-supply cord    
 

or plug is damaged, liquid has been spilled, or objects have fallen into the device, the device has been exposed to rain or moisture, does not  

 

 

operate normally, or has been dropped. 

16. 

WARNING:

 To reduce the risk of fire or electric shock, this device should not be exposed to rain or moisture and objects filled with liquids, such as  

 

a vase, should not be placed on this device. 

17.  To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle. 
18. The mains plug of the power supply cord shall remain readily operable.
19. 

Protective earthing terminal. The apparatus should be connected to a mains socket with a protective earthing connection.

The lightning flash with arrowhead symbol within an equilateral triangle, 
is intended to alert the user to the presence of uninsulated “dangerous 
voltage “ within the product’s enclosure that may be of sufficient 
magnitude to constitute a risk of electric shock to persons. 

The exclamation point within an equilateral triangle is intended to 
alert the user to the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the product. 

WARNING: SHOCK HAZARD - DO NOT OPEN

AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE

AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE

Summary of Contents for ASP-MG24

Page 1: ...1 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A ASP MG24 ASP MG24TDB Signal Processor Masking Generator 2 Input x 4 Output...

Page 2: ...TEXAS 75119 U S A Table of Contents Important Safety Instructions 3 Introduction 5 Key Features 5 Front Panel Description 6 Rear Panel Description 7 Getting to Know the Software 8 Mic Line Input 9 Ma...

Page 3: ...our electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 14 Unplug this device during lightning storms or when unused for long periods of time 15 Ref...

Page 4: ...connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not mod...

Page 5: ...ections 31 band EQ white pink noise auto ramp routing mixing and compressor limiters The ASP MG24 can be controlled or configured in real time with the intuitive PC GUI accessed via the RS 232 or USB...

Page 6: ...2 Level LED Indicators 5 LEDs per channel indicate the status of the signal level Signal 12dB 6dB 3dB Over Limit A dual use LED indicates maximum headroom and limiter threshold 3 RS232 Connector Stand...

Page 7: ...lying signal to the input set the analog gain switch to match the type of input being used The Line position gain is calibrated for 0dBu or unity gain within the DSP software The Mic position gain is...

Page 8: ...rsonal viewing preferences 3 After the software is loaded and the proper screen resolution is set open the software and follow the steps below Note It is not necessary to have the computer connected t...

Page 9: ...d is PRE input filters and compressor settings Gain For convenience both Mic Line inputs and the four masking generators levels are shown Controlling the gain can be accomplished by dragging the fader...

Page 10: ...second is the settings screen This screen controls Threshold Attack Release and Ratio Adjustment can be made using the up down arrows or by typing into the data viewing text box Threshold Limit thresh...

Page 11: ...tion Also use the screen curser up down arrows to find the three screens All 3 screens can be moved by clicking and holding the selected screen for personal viewing preferences Graphic Screen This scr...

Page 12: ...AS 75119 U S A Crossover Window The Crossover window allows the adjustment of filter type frequency and slope The Reset button will set all filters back to factory settings and only affects the settin...

Page 13: ...red turn on signal ramp time during power up The Time buttons allow adjustment of the amount of preset time needed The amount of steps is a formula of gain divided by time The ramp interval voltage ch...

Page 14: ...l Mute can be accomplished by clicking on the Mute button It will illuminate red indicating the channel is in Mute Masking EQ When clicking on the filter screen 3 sub viewing screens appear Note All 3...

Page 15: ...settings and only effects the settings in this screen There are 20 1 3 octave band filters available to adjust the measured masking signal A generous 15dB and 30dB boost and cut are offered in 0 25dB...

Page 16: ...to 0dB Controlling the mixed gain can be accomplished by dragging the fader using the up down buttons or typing in the number viewing text box Note The signal feeding into the mixer will not be effect...

Page 17: ...screens can be moved for personal viewing preferences Graphic Screen This screen will display all of the filter characteristics that are set Filter Window Each input has 8 adjustable filter selection...

Page 18: ...Delay Window The Delay window allows adjustment of the channel delay from 0ms to 200ms per output Controlling the mixed gain can be accomplished by using the up down buttons or by typing in number vi...

Page 19: ...ndicator screen showing the compressor limiter operation Screen 2 is the settings screen which controls Threshold Attack Release and Ratio Adjustment can be made using the up down arrows Threshold Lim...

Page 20: ...BLVD ENNIS TEXAS 75119 U S A Mute Channel Mute can be accomplished by clicking on the Mute tab and will illuminate red indicating the channel is in Mute Output Meter The bar graph meter illustrates t...

Page 21: ...and Export Master Reset All This button is the master reset button and will override all settings Note A confirmation widow will pop up File Open Program files can be recalled from the PC or Laptop It...

Page 22: ...in non volatile memory that can store up 14 different program setups A program can be recalled from the device When doing so only one program can be open on the desktop GUI Once recalled the program...

Page 23: ...rs and sound masking setups Meter Real time meters for all inputs outputs Scaled in V RMS dBu and dBV These are helpful when troubleshooting Scheduler The ASP MG24TDB contains a programmable clock and...

Page 24: ...ck the Initial Ramp Commission button 2 Click the Start Date drop down menu and select the start date 3 Set the start level for the masking signal typically 10dB down from the target level 4 Click the...

Page 25: ...allow selection of any of the 4 masking channels and 2 inputs to be configured to a schedule as well as choosing the day of the week to program To reduce data entry time create a schedule for one day...

Page 26: ...uts 4 Outputs 3 pin Balanced Phoenix DC Power Receptacle 5 Pin DIN Connector Audio Control Parameters Gain 40dB to 15dB in 0 25dB Steps Polarity Delay Up to 200ms per I O Parametric Filters 8 per I O...

Page 27: ...ters High Performance 24 bit Propagation Delay 3ms Electrical Specifications General Input Impedance Line 10k Ohms Mic Output Impedance 50 Ohms Maximum Input Output Level 20dBu Frequency Response 20Hz...

Page 28: ...T ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Dimensional Drawings Power Data ASP MG24 2x4 Signal Processor Masking Generator 1 2 Over Limit 3dB 6dB 12dB Signal Inputs RS232 USB 1 2 3 Ou...

Page 29: ...29 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Page 30: ...30 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Page 31: ...31 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Page 32: ...ed or operated in excess of rated power altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this...