Front Panel
1. Unswitched AC Outlet
The 120VAC outlet is always live when the AP-S15LA power cord is plugged into an AC mains power source.
Note:
The AC mains power switch does
not affect the Unswitched AC Outlet but it is protected with surge protection circuitry.
2. Power Switch & Cover
To turn the AP-S15LA On or Off, press the switch to the On (up) or Off (down) position. When the Power Switch is in the On (up) position and the
power cord is plugged into 115V - 120V and voltage is present, the Blue Power LED will illuminate. When the Power Switch is in the Off (down)
position the Blue Power LED will not be illuminated.
Note:
The Protect and Ground LEDs will be illuminated when the Power Switch is in the Off
(down) position when operating correctly. The AP-S15LA incorporates a power switch cover to prevent accidental pressing of the power switch.
3. Switched Outlets Active Indicator
This LED will illuminate Blue when the power switch is in the On position.
4. Surge Protect Indicator
The Surge Protect LED is illuminated Red under normal operating conditions showing that the surge protection circuit is functioning correctly and the
connected equipment is protected from voltage transients.
Note:
The Surge protection LED will be illuminated regardless of the Power Switch being
in the On or Off position. Although the clamping suppression circuit virtually assures protection from most transient voltage spikes and surges, nature
has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage. In the
rare instance that this occurs and the circuit has been damaged, the Red “Surge Protect” LED indicator will turn
Off
. If the Surge Protection LED in
off, all AC outlets will remain functional but the device will have no surge protection. It is recommended to stop using the unit or future damage may
occur to the devices connected to this unit. Be advised that activation of this fault condition and the associated repair is not covered under warranty.
Note:
If the Surge Protect LED is not illuminated while the unit is powered on, it is important to have all equipment that was connected to that AC
Mains Line inspected for proper operation.
5. Ground Status Indicator
This LED will illuminate Green regardless of the Power Switch being in the On or Off position and when the AP-S15LA has Earth ground connection
on the Earth ground pin of the AC Mains power cord. If the Ground Status LED in off, all AC outlets will remain functional but the device will have no
Earth ground. It is recommended to stop using the unit or future damage may occur to the devices connected to the unit.
Note:
If there is no Earth
ground connection the LED will not illuminate and the AC wall outlet must be repaired by a qualified electrician before continuing.
6. Pull Out Lamp
Pull the lamp out to illuminate equipment mounted below the AP-S15LA. The brightness of the lamp can be adjusted with the dimmer switch to the
left of the lamp.
7. Pull Out Lamp Dimmer
Adjust the intensity of the pull out lamp by turning the dimmer switch.