5.7
Manual loading/unloading
Control panel
Control panel of controller
General
Normally, the compressor runs in automatic operation, i.e. the electronic regulator loads, unloads,
stops and restarts the compressor automatically. Sign (4) is then alight.
If required, the compressor can be unloaded manually. In this case, the compressor is switched
out of automatic operation i.e. the compressor remains running unloaded unless it is loaded
again manually.
Manual unloading
Starting from the main screen, select Unload. The compressor starts running unloaded and sign
(4) fades. The message
Manual Unload
appears on the display.
Manual loading
Starting from the main screen, select Load. Sign (4) lights up and the compressor starts running
loaded in case the air net pressure drops below the programmed level. The message
Load
appears on the display.
Instruction book
86
AIF999999