- 52 -
AIR RECEIVER
The air receiver (1) is tested according to
official standards. Regularly have
inspections carried out in conformity with
local regulations.
SAFETY VALVE
Following checks must be carried out:
•
A check of the opening of the lifting
gear, twice a year.
This can be done by screwing the cap of
the valve anti-clockwise.
•
A check of the set pressure once a year
according to the local regulations. This
check cannot be done on the compressor
and must be carried out on a proper test
bench.
Daily drain condensate.
All adjustments or repairs are to
be done by an authorized
representative of the safety valve
(2) supplier, see section Specific
Summary of Contents for XAHS 186 Cud PNE