Peripheral Devices
9836 3521 01
619
8.17.5.9 Sequence and Program, Step, Speed, Ramp down data
Syntax:
Program[
<
pgm name
>
].Step[
<
step no
>
].Speed.RampDown[
<
ramp
>
].
<
parameter
>
Sequence[
<
seq name
>
].Step[
<
step no
>
].Speed.RampDown[
<
ramp
>
].
<
parameter
>
<
pgm name
>
= The name of the program
<
step no
>
= Step number, 1..50
<
ramp
>
= Ramp number, 1..5
<parameter>
= See table below (and Step
– for a description)
<parameter>
Data type
Description
Start
Short integer
Defines the quantity to monitor as start condition.
Allowed values:
1. Torque
2. Angle
3. Current
4. Time
Level
Float
The trig level of the measured quantity.
Speed
Float
The new target speed.
Ramp
Float
The ramp to use when changing the speed.
Example:
Program[Pgm01].Step[1].Speed.RampDown[1].Start