Basic Functions
60
9836 3521 01
3.6.1.1 Station Views
For a station, different background pictures and layouts of the station and bolt boxes can be used. The
currently selected Mode number triggers which so called Station View to display. The mapping between
Station Views and Mode numbers are done using the Assembly Overview Set Up form.
The Station View change is triggered by a change in the Mode number. That means that if the Mode
number is changed before a cycle is started, the Station View is also changed before the cycle is started.
Changing Mode number is done by using the PLC station output variable MODE (see Station variables). If
a cycle is running when the Mode number changes, the Station View is not changed until the cycle is
finished.
If the Mode number changes to a Mode number that does
not
map to any Station view (or the Mode
number is reset to zero), the currently shown Station View remains.
When the Station View changes, the status color and result variables of all station and bolt boxes remains.
If it is desired to clear these values, use the PLC station output variable RESETSTATUS (see Station
variables). A positive edge on this variable will cause all result information in Assembly Overview to be
cleared and set the background color of all station and bolt boxes to grey. The status information in the
System Map will also be cleared.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...