Peripheral Devices
9836 3521 01
477
Value sent
Meaning
Corresponding PowerMACS error
20
Current max
CH, current high from check
21
Current min
CL, current low from check
22
Security, MD
TR, torque restriction
23
Security, WI
AR, angle restriction
499
Other error
If any other error code is set.
8.11.5.4
Characteristic Identifications
Identification
Meaning
Value sent
Unit
WI
Actual value angle
Bolt A
Grad
MI
Actual value torque
Bolt T
Nm
GI
Actual values gradient
Bolt TR1
Nm/Gr
TI
Actual value time
Only sent as trace data
S
MR
Redundancy Torque
Bolt A 2
nd
Grad
WR
Redundancy angle
Bolt T 2
nd
Nm
8.11.5.5
Parameter Identifications
Identification
Meaning
Value sent
W-
Lower tolerance angle
Bolt A low limit
W+
Upper tolerance angle
Bolt A high limit
M-
Lower tolerance torque
Bolt T low limit
M+
Upper tolerance torque
Bolt T high limit
G-
Lower tolerance gradient
Bolt TR1 low limit
G+
Upper tolerance gradient
Bolt TR1 high limit
MS
Threshold
Bolt A Thresh T
Summary of Contents for PowerMACS 4000