Tightening
344
9836 3521 01
6.5.4.18 Check Backlash angle (only available for Gauging)
Parameters
:
Backlash angle high, Backlash angle low
Function:
The backlash angle used in the step (measured by the last BCT step ran) is compared to
the limits
Backlash angle high and Backlash angle low
. Both or only one of the limits can
be programmed.
Result var:
"BCT A", "BCT A1", "BCT A2" (Backlash angle)
Alarms:
Backlash angle high (BAH) and Backlash angle low (BAL).
Trace
:
No limits are shown in trace.
6.5.4.19 Check external input (only available for Gauging)
Parameters
:
Digital Input, Signal Value
Function:
The selected
Digital Input
is compared to the
Signal Value
at the end of the step, after the
over shoot time has passed.
The following digital signals are available for
Digital Input
:
Local DI 1, … Local DI 4
(the digital outputs directly on the TC)
PLC_DO
_1, … PLC_DO_10
(avalible as outputs in the PLC)
Possible
Signal Value
are
Low
or
High
Result var:
None
Alarms:
Step input not OK (NOKINPUT).
Trace
:
No limits are shown in trace.