6.5.4.3 Check torque in angle window
Parameters:
TH
(Torque high),
TL
(Torque low),
Astart
,
Astop
Function:
Astart
and
Astop
are both measured from the start of the step and define an angle window.
All torque values measured in this window are checked to be between the high limit
TH
and
the low limit
TL
.
Both limits are optional. Leaving them blank disables the check but the result values are still
calculated and reported.
This check requires that at least one sample is collected after the torque spike elimination
phase and that angle
Astop
is reached. If not, and at least one limit is specified, the steps
status is set to
Fatal
and the error bit of respective limit is set.
Diagram:
Angle
Torque
AStop
AStart
TL
TH
TH
Torque High
AStart
Angle start
TL
Torque Low
AStop
Angel stop
A Win Hi T
A Win Lo T
Step
Result var.:
"A Win Hi T" (angle window high torque) and "A Win Lo T" (angle window low torque).
Alarms:
Step torque high in angle window (THAWIN) and step torque low in angle window
(TLAWIN).
Trace
:
TH and TL are shown in trace as horizontal lines from AStart to AStop. The lines are only
shown when Torque vs. Angle is selected and Check limits are enabled in the trace form
(see
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...