- 53 -
5.5.6
Ordering spare parts
It is possible to order spare parts for the light tower by
making reference to the parts as mentioned in the
enclosed Parts List manual.
Always quote the part number, the designation and
the quantity of the parts required, as well as the type
and the serial number of the machine.
5.6
Resetting service alarms
The alarm must be accepted and the alarm condition
cleared to reset the Lc1003™ module.
1. Stop the unit.
2. Scroll
UP
or
DOWN
through the maintenance
alarms.
3. On each maintenance alarm screen press and hold
the
STOP/RESET
button for 10 seconds.
4. A password will be requested.
5. Enter password
1968
and push the
AUTO
button
to accept the alarm.
5.7
Engine consumable
specifications
5.7.1
Engine fuel specifications
For fuel specifications, please contact your Atlas
Copco Customer Center.
5.7.2
Engine oil specifications
High-quality, mineral, hydraulic or synthesized
hydrocarbon oil with rust and oxidation inhibitors,
anti-foam and anti-wear properties is recommended.
The viscosity grade should correspond to the ambient
temperature and ISO 3448, as follows.
Specifications PAROIL
PAROIL from Atlas Copco is the ONLY oil tested
and approved for use in all engines built into Atlas
Copco compressors, generators and light towers.
Extensive laboratory and field endurance tests on
Atlas Copco equipment have proven PAROIL to
match all lubrication demands in varied conditions. It
meets stringent quality control specifications to
ensure your equipment will run smoothly and
reliably.
The quality lubricant additives in PAROIL allow for
extended oil change intervals without any loss in
performance or longevity.
It is strongly recommended to use
Atlas Copco branded lubrication oils.
Engine
Type of lubricant
between -10°C and 50°C
PAROIL E or
between -25°C and 50°C
PAROIL Extra
Never mix synthetic with mineral
oil.
When changing from mineral to
synthetic oil (or the other way
around), you will need to do an
extra rinse.
After doing the complete change
procedure to synthetic oil, run the
unit for a few minutes to allow good
and complete circulation of the
synthetic oil. Then drain the
synthetic oil again and fill again
with new synthetic oil. To set correct
oil levels, proceed as in normal
instruction.
00_00_HiLight H4_EN.book Page 53 Monday, April 18, 2016 2:10 PM
Summary of Contents for HiLight H4 Kd ESF
Page 2: ...00_00_HiLight H4_EN book Page 2 Monday April 18 2016 2 10 PM ...
Page 81: ... 81 Circuit diagrams 00_00_HiLight H4_EN book Page 81 Monday April 18 2016 2 10 PM ...
Page 85: ... 85 00_00_HiLight H4_EN book Page 85 Monday April 18 2016 2 10 PM ...
Page 90: ... 90 00_00_HiLight H4_EN book Page 90 Monday April 18 2016 2 10 PM ...
Page 93: ...00_00_HiLight H4_EN book Page 93 Monday April 18 2016 2 10 PM ...
Page 94: ......