Text on drawing
Reference
Designation
(1)
Customer’s installation
(2)
Option
(3)
All other voltages except 440-460 V - 60 Hz
(4)
Remote start/stop
(5)
Motor protection
(6)
Emergency stop
(7)
Remote emergency stop
(8)
Supply of dryer
(9)
All other voltages
Designations used
Typical references used in the electric diagram of the compressor:
Reference
Compressor
A1
Dryer
M1
Compressor motor
PT20
Pressure sensor, air delivery
TT11
Temperature sensor, element outlet
TT90
Temperature sensor, LAT dryer (GA Full-Feature only)
Y1
Solenoid valve
Reference
Starter cubicle
E1
Elektronikon regulator
F1, F2,...
Fuses
F21
Overload relay, compressor motor
K11
Contactor for dryer supply (GA Full-Feature only)
K21
Line contactor
K22
Star contactor
K23
Delta contactor
K5
Auxiliary relay, motor protection
S’
Remote pressure sensing
S1’
Remote start/stop
S3
Emergency stop
S3’
Remote emergency stop
T1
Transformer
1X0
Power supply connection
1X1
Motor connection
1X3
Earth connection
X101/X108
Connectors
Instruction book
API451763
23