8. Reset the service warning after carrying out all service actions in the relevant Service Plan:
For compressors with Elektronikon® controller, see section
Calling up/resetting the service timer
For compressors with Elektronikon® Graphic controller, see section
12.4 Oil separator change
Warning
The operator must apply all relevant
.
Procedure
1. Run the compressor until warm. Stop the compressor, close the air outlet valve and switch off the
voltage. Wait a few minutes and depressurise by unscrewing oil filler plug (FC) just one turn to
permit any pressure in the system to escape.
2. Wait 5 minutes and remove the oil separator (OS). Clean the seat on the manifold. Oil the gasket of
the new separator and screw it into place. Tighten firmly by hand.
3. Reset the service timer:
For compressors equipped with an Elektronikon® regulator, see section
For compressors equipped with an Elektronikon® Graphic regulator, see section
.
12.5 Coolers
General
Keep the coolers clean to maintain their efficiency.
Never use a high pressure water jet to clean the compressor.
Instructions for air-cooled compressors
• Stop the compressor, close the air outlet valve and switch off the voltage.
• Cover all parts under the coolers.
• Remove any dirt from the coolers with a fibre brush. Never use a wire brush or metal objects.
• Next, clean with an air jet in the reverse direction to normal flow. Use low pressure air. If necessary,
the pressure may be increased up to 6 bar(e) (87 psig).
• If it is necessary to wash the coolers with a cleaning agent, consult Atlas Copco.