Condensate drains on a receiver-mounted compressor
All Tank-mounted versions except Tank-mounted compressors without optional dryer are
equipped with a condensate trap in the air outlet system. The trap is equipped with a valve for
automatic draining during operation (Da) and a manually operated valve (Dm) for draining after
stopping the compressor.
Tank-mounted compressors are provided with a manual condensate drain valve (Dm1).
2.6
Regulating system
Description
If the consumption is less than the air output of the compressor, the net pressure increases.
When the net pressure is higher than the set-point (desired net pressure), the regulator will
decrease the motor speed. If the net pressure keeps on rising when the motor runs at minimum
speed, the regulator will unload the compressor for 40 seconds, after which the motor is stopped.
If the motor is stopped automatically and the net pressure approaches the set-point, the regulator
will restart the motor.
2.7
Electrical system
General
Electric cabinet
The electrical system comprises the following components: