3 .3 Check and connecting
"
The refrigerant circuit is very sensitive
to dust and humidity: check that the area
around the connection is clean and dry before
removing the plugs protecting the refrigerant
connectors .
"
Indicative blowing value:
6 bar during 30
seconds minimum for connection of 20 m .
"Gas" connection control (large diameter)
.
Connect the "Gas" connection to the outdoor unit.
Blow dry nitrogen into the "Gas" connection and observe
this end:
-
If water or impurities emerge, use a new refrigerant
connection
Otherwise, perform the flare and connect immediately
the refrigerant connection to the hydraulic unit.
"Liquid" connection control (small diameter)
.
Connect the "Liquid" connection to the outdoor unit.
Blow dry nitrogen into
"Gas" connection – condensor
- "Liquid" connection
assembly and Observe this end
(Outdoor unit side).
-
If water or impurities emerge, use a new refrigerant
connection
-
Otherwise, perform the flare and connect immediately
the refrigerant connection to the outdoor unit.
Remarks :
"
Take particular care positioning the tube opposite
its connector so as not to risk damaging the
threads. A carefully aligned connector can be fitted
easily by hand without much force being required.
-
Comply with the indicated tightening torques.
figure 24 - Tightening torques
Designation
Tightening torque
Flare nut 6.35 mm (1/4")
14 to 18 Nm.
Flare nut 9.52 mm (3/8")
33 to 42 Nm.
Flare nut 12.7 mm (1/2")
50 to 62 Nm.
Flare nut 15.88 mm (5/8")
63 to 77 Nm.
Plug (A) 3/8", 1/4"
20 to 25 Nm.
Plug (A) 1/2"
25 to 30 Nm.
Plug (A) 5/8"
30 to 35 Nm.
Plug (B) 3/8", 5/8"
10 to 12 Nm.
Plug (B) 1/2", 1/4"
12.5 to 16 Nm.
Spanner
Torque wrench
figure 25 - Refrigerant connections check
Nitrogen
Nitrogen
Nitrogen
"Gas"
connection
"Gas"
connection
"Gas"
"Liquid"
connection
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 26 -
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...