background image

I N S T R U C T I O N   M A N U A L

www.W AT E R S C A P E S I N T E R N AT I O N A L .com

Summary of Contents for Waterscapes BF1000

Page 1: ...I N S T R U C T I O N M A N U A L www WAT E R S C A P E S I N T E R N AT I O N A L com...

Page 2: ...he Echo Chamber Page 9 Liner Attachment Page 9 FASTFALLS INSTALLATION Bulkhead Installation Page 10 Setting the FastFalls Page 11 Liner and Plumbing Attachment Page 11 TABLE OF CONTENTS 2 PRODUCT SPEC...

Page 3: ...pond and the water levels equalize During water in transition process the water level of the bottom reservoir is continually dropping If the streambed is built improperly or is built too big the water...

Page 4: ...reambed and enables the system to function optimally Transitional water is determined by the height that the weir rock extends above the liner at the spillway opening Maintaining the shortest distance...

Page 5: ...t there is enough room for the weir door to be installed and function properly Before you go any further into the Skimmer installation place a few stones inside the Skimmer enclosure to weigh it down...

Page 6: ...flange nuts Next install two screws in the bottom corners of the weir door frame Figure 8 Once you have the weir door tacked at the corners you can install the rest of the screws Do not fully tighten...

Page 7: ...aced adjacent to the pond edge to create a single waterfall or pulled away from the pond to create a streambed effect Refer to the surface area recommendations on page 3 to ensure that the streambed i...

Page 8: ...o seal the back of each screw with a dab of silicone on the inside of the enclosure Figure 9 ECHO CHAMBER VS GRAVEL BASIN FOR A WATERFALL OR STREAM Gravel basins consist of 70 rock and only 30 water E...

Page 9: ...pport tubes must be in place for the enclosure to retain its shape during the back filling process Loosely backfill the Echo Chamber on all sides lightly compacting as you go Do not over compact the s...

Page 10: ...ting and proper hose adaptor not included before setting the FastFalls The SP1400 comes pre drilled for a 1 bulkhead fitting while the SP2500 SP3600 come pre drilled for a 2 bulkhead fitting The SP480...

Page 11: ...stalled tilted slightly forward about This will ensure that water never leaks out over the back of the enclosure LINER ATTACHMENT SP1400 SP2500 SP3600 SP4800 Dry fit the liner Hold the liner up agains...

Page 12: ...www WAT E R S C A P E S I N T E R N AT I O N A L com...

Reviews: