5. Technical data
Model
200 liters
270 liters
Dimensions ( Height x Width x Depth)
mm
1609 x 620 x 665
1949 x 620 x 665
Empty weight (model without coil)
kg
85
93
Empty weight (model with coil)
kg
100
108
Nominal capacity
L
200
270
Hot and cold water connecBon
¾
ʺ
M
Coil’s connecBon
1
ʺ
M
Coil’s heaBng surface
m²
1,2
Coil’s power at T
Primary
60°C and flow 1,5m
3
/h
kW
16
AnBcorrosion system
ACI Hybrid
Rated water pressure
Bar
8
Electrical connecBon (voltage/frequency)
-‐
230V single phase 50 Hz
Maximal total power absorbed by the device
W
2465
Maximal power absorbed by the heat pump
W
665
Power absorbed by the auxiliary electrical unit
W
1800
Heat pump water temperature sejng range
°C
50 to 62
Heat pump user temperature sejng range (air temperature)
°C
-‐5 to +43
Duct diameter
mm
160
Air flow (without duct) at low speed
m
3
/h
300
Air flow (without duct) at high speed
m
3
/h
390
Load losses acceptable on venBlaBon circuit, without affecBng
performance
Pa
25
Sound power level
dB(A)
50,3
Sound pressure level at 2m
dB(A)
33,5
R134a refrigerant capacity
kg
1,25
1,35
Hot water quanBty at 40° : V40td in 8h(Off-‐peak)
L
312
347
Hot water quanBty at 40° : V40td in 14h (Off-‐peak+6h)
L
579
607
Performance at 7°C air temperature (EN 16147)
Coefficient of performance (COP)
-‐
2,8
2,9
Tapping cycle
-‐
L
XL
Standby power input (P
es
)
W
27
30
HeaBng up Bme (t
h
)
h.min
7h54
10h41
Reference hot water temperature (T
ref
)
°C
54
52,9
Flowrate (air)
m
3
/h
305,7
287,6
This device is compliant with direcBves 2004/108/CEE on electromagneBc compaBbility and 2006/95/CEE on low voltage.