Atlantic HPWH 200 Lt Installation And Operation Manual Download Page 26

Mode   MANUAL   :   

This    mode    allows    to    define    the    desired    hot    water    quanBty    by    selecBng    the    set    temperature.    The    set   

temperature   is   also   displayed   as   equivalence   of   showers                           :   about   50   L   of   hot   water).   
   

When   the   mode   ECO   is   not   acBvated,   the   water   heater   favors   the   operaBon   of   the   heat   pump.   However   if   
the   air   temperature   is   low   or   the   water   consumpBon   high,   the   electric   (or   boiler)   backup   can   be   used   at   the   

end   of   the   heaBng   cycle   to   reach   the   set   temperature.   

   
When    the    mode    ECO    is    acBvated,    the    water    heater    works    exclusively    with    the    heat    pump    in    the    air   

temperature   range   of   -­‐5   to   +43°C.   The   electric   backup   heater   is   not   used.   This   funcBon   maximizes   the   energy   
savings   but   can   cause   a   lack   of   hot   water.   

   

Whatever   sejng   of   ECO,   the   electric   backup   heater   is   used   automaBcally   if   the   air   temperature   is   outside   the   
working   range   to   assure   a   sufficient   hot   water   volume.   

Overview   

InstallaBon   

OperaBon   

Maintenance   

Warranty   

10.6.   Choice   of   operaJng   mode   

Press   the   buTon   

      to   access      the   menu                                                

Mode   

Mode   AUTO   (only   available   on   installaJons   «heat   pump   only   »)   :   

This    operaBng    mode    manages    automaBcally    the    choice    of    energy    allowing    to    maximize        economies    while   

supplying   a   sufficient   hot   water   comfort   level.   
The   water   heater   analyses   the   water   consumpBon   of   the   previous   days   to   adapt   the   hot   water   producBon   as   

required.    It    reacts    to    unplanned    events    by    launching    working    cycles    during    the    day    to    assure    enough    hot   
water.   The   set   temperature   varies   automaBcally      between   50   and      62°C   according   to   the   consumpBon   profile.   

The    water    heater    chooses    preferably    the    heat    pump.    The    electric    backup    can    automaBcally    be    added        to   

provide   the   correct   hot   water   volume.   

10.7.   Locking   of   interface   

Press                                    for   some   seconds   to   lock/unlock   the   interface.                                             

Mode   MANUAL   on   installaJon   «   Solar   backup   »   

This    mode    allows    the    work    of    the    heat    pump    in    combinaJon    with    a    solar    backup.    However    the   

simultaneous    working    of    the    heat    pump    and    the    solar    backup    can    damage    the    product.    The    heat   
pump   must   be   used   in   periods   when   solar   energy   is   not   available   (to   do   this   use   the   programming   

mode   of   the   water   heater)   

This   mode   is   not   available   on   installaJons   «   boiler   backup   »   and   «   solar   backup   »         

The   mode   ECO   acJvated/not   acJvated   can’t   be   changed   on   installaJons   «   Boiler   backup   »            

The   mode   BOOST   :

   this   mode   acBvates   the   heat   pump   and   all   other   available   energy   sources   (boiler   backup   if   

set,   electric   backup)   at   the   same   Bme   to   reach   the   maximum   set   point   of   62°C.   

   

The   mode   ABSENCE   :

   this   mode   maintains   the   hot   water   temperature   above   15°C   by   using   the   heat   pump.   

The   boiler   and   electric   backup   can   be   used   if   the   heat   pump   is   not   available.   
   

The   mode   LOOP   :   

this   mode   allows   the   heat   pump   to   work   permanently   to   reach   the   set   point   of   62°C.   The   

backups   (boiler   if   set   and   electric)   may   be   used   acer   7h   of   operaBon   of   the   heat   pump.   

25   

Summary of Contents for HPWH 200 Lt

Page 1: ......

Page 2: ...e warranty does not cover damage of the appliance through excessive water pressure caused by faulty pressure limiBng or control valves 2 Ensure that the floor on which it is mounted can support the weight of the appliance filled with water 3 If the appliance has to be installed in a room or locaBon with an ambient temperature always above 35 C this room must be venBlated 4 Place the appliance in an ...

Page 3: ...ted to external drain 2 Hot Water Outlet Where a maximum hot water delivery temperature is specified by Local State or Federal RegulaBons a Tempering Valve shall be installed at the Hot Water Outlet as required The included specified Pressure Temperature Relief Valve must be installed as shown in the schemaBc The PTR valve should be connected to a drain point to accommodate discharge as a result of ...

Page 4: ...cal Wiring Rules of Aus NZ Circuit IsolaBon and fixed appliance regulaBons of the Wiring rules shall be complied in regard to connecBon to supply circuit isolaBon and protecBon 3 Dielectric itting Supplied Connection tee Supplied PTR Valve 700 kPa Untempered hot water Kitchen laundry Tempered water 50 C Bathrooms Cold water main supply Non return and isolating valve Line Strainer Drain lines Pressu...

Page 5: ...ter heater may be filled with cold water and flushed through to ensure the cylinder contains no sediment and is clean Finally the closest hot taps are closed and power may be turned on again to the completely filled water heater In the event of an anomaly the heater does not heat or steam is released from the Pressure Temperature Relief valve switch off the electric power supply and contact your resel...

Page 6: ...Not Allowed configuraBons 6 Hydraulic connecBon 7 Air connecBon 8 Electric connecBon 9 ConnecBon of opBonal equipment 10 Commissioning OperaBon 1 Interface 2 DescripBon of pictograms 3 Main menu 4 The operaBng modes Maintenance 1 Advice to the user 2 Service 3 Open the water heater for maintenance 4 Trouble shooBng Warranty 1 Scope of warranty 2 Warranty condiBons 3 Warranty registraBon 1 4 1 5 6 7...

Page 7: ...ck that the product has been transported and handled in accordance with our recommendaJons We recommend you should be careful to respect these instrucJons Our warranty will not apply if the inclinaJon indicator is red We will not be responsible for any fault in the product resulJng from transport or handling of the product in a way that does not comply with our recommendaJons 2 Content of package ...

Page 8: ...s components including the evaporator As it passes through the evaporator the coolant evaporates and conveys calories to the intake air The compressor compresses the coolant causing its temperature to rise This heat is transmiTed by the condenser to the domesBc water stored in the cylinder The coolant expands in the thermostaBc expansion valve and cools down It is then once again ready to receive ...

Page 9: ...00 Heat pump water temperature sejng range C 50 to 62 Heat pump user temperature sejng range air temperature C 5 to 43 Duct diameter mm 160 Air flow without duct at low speed m3 h 300 Air flow without duct at high speed m3 h 390 Load losses acceptable on venBlaBon circuit without affecBng performance Pa 25 Sound power level dB A 50 3 Sound pressure level at 2m dB A 33 5 R134a refrigerant capacity kg ...

Page 10: ...nsate outlet 1221 1221 1562 1562 B Total height 1609 1609 1949 1949 C Cold water inlet 304 462 304 462 D Hot water outlet 961 961 1300 1300 E Total width 620 620 620 620 F Total depth 665 665 665 665 G Distance between air inlet and outlet 418 418 418 418 H Coil inlet 581 581 B A D C E F 60 Dimensions in mm H 104 9 ...

Page 11: ...Fan plate support 23 Front column 24 Lower column plug 25 ACI wire 26 RegulaBon controller PCB 27 Compressor wire 28 Water sensor wire 29 Electrical backup wire 30 Heat pump sensors wire 31 Fan wire 32 Controller wire 33 Compressor jacket cover 12 Capacitor 1 5µF 13 Capacitor 4µF 14 Terminal connecBon block 15 Front cover 16 Compressor 17 Compressor jacket 18 Guide support rail 19 Hybrid heaBng sl...

Page 12: ...ct orientaBon of the cover posiBons when installing There are no operaBonal clearance limitaBons to surrounding structure PTR valve removal requires approximately 150 mm for withdrawal AS NZS 3500 4 2 NaBonal plumbing drainage Hot Water Supply Systems Acceptable soluBons The floor has to support a load of 400 kg minimum surface below the water The selected place of installaBon has to conform to the...

Page 13: ...room where average yearly temperature is 10 C Keep a free space of 500 mm in front of electric compartment and 300 mm around hydraulic connecJons to allow easy access for maintenance Examples Garage recovery of free energy from combusBon engine or of domesBc devices Washing room reduce humidity of the room and recover lost energy of washing machine and dryer 400mm min It is mandatory to respect in...

Page 14: ...ernal walls Avoid installaBon of water heater and or ducts near to sleeping rooms Examples Washing room Storage room Cupboard in entry area 670mm min Keep a free space of 500 mm in front of electric compartment and 300 mm around hydraulic connecJons to allow easy access for maintenance 100mm min 620mm 120 mm min Respect the maximum length of ducts Use insulated ducts Install mesh vents for air in ...

Page 15: ...room generated by the air extracJon causes fresh air entry through doors and windows Plan an air entry Ø 160mm from outside to avoid air sucking from heated living area In winter Jme the renewed air can cool the room Keep a free space of 500 mm in front of electric compartment and 300 mm around hydraulic connecJons to allow easy access for maintenance 620mm 670mm min 120mm min Examples Garage reco...

Page 16: ...ecBon to an underground air duct Water heater installed in a room together with a boiler connected to a chimney with natural drac and 1 duct to outside Direct air connecBon to a cloth drying machine InstallaBon in dusty rooms Intake of air with solvents or explosive materials Direct air connecBon to cooking hoods with polluted and faTy air InstallaBon in a room where freezing temperature can occur...

Page 17: ...ng the tank or the water heater Cold water piping should be provided with a 350 500 kPa Pressure LimiBng Valve at the point of cold water connecBon to the water heater In addiBon to the Pressure LimiBng Valve It is a requirement of AS 3500 4 NZBC G12 that both a Stop Valve and a Non Return Valve are installed upstream of the Product No parts stop valve pressure reducer etc must be placed between t...

Page 18: ... directly on the tank connecJon You have to fit the supplied insulaJon union included in the supply In case that the tank connecJon is corroded without this protecJon the warranty will not apply If the circulaJon connecJon is not used install the plug and seal on this connecJon included in the supply 6 4 ConnecJon of primary circuit for water heater with coil Protect the circuit against over pressu...

Page 19: ...nd exit Unscrew the fixing s c r e w s o f t h e a i r connecBon then turn in the required direcBon Rotate again by 120 posiBon to the opposite sides Rotate by 120 posiBon to the rear A poor duct installaBon duct compressed length or number of bends too high can reduce the performance The ducts can be fiTed directly on the rotaBonal air in outlets EXIT ENTRY Note The rotaBonal air connec ons allow t...

Page 20: ...5 mm If the power cable is damaged the manufacturer the acer sales service or similarly qualified people must replace it to avoid danger The security thermostat fiTed to the auxiliary electric heaBng element must be replaced by an authorised agent Failure to respect this clause invalidates the warranty Electrical work must be carried out by a licensed tradesperson and in accordance with Electrical W...

Page 21: ... Once the photovoltaic panels produce enough energy the inverter sends a signal to the water heater which switches into a special mode PV acBvaBng the heat pump If the inverter signal stops the water heater switches automaBcally back to the previous operaBng mode In this PV mode the set temperature is changed to 62 C no modificaBon possible and on the display appears PV The water heaters linked to ...

Page 22: ...on should be done on the contacts B1 and B2 of the connecBon board 9 3 ConnecJon to a solar staJon Electric power supply Solar contact 230V A1 A2 B1 B2 C1 C2 Overview InstallaBon OperaBon Maintenance Warranty 9 4 InstallaJon of the solar sensor Take off the plasBc cap and the foam plug located near the exchanger connecBons Push the sensor through the plasBc cap the cap has dedicated perforaBons Ins...

Page 23: ...water heater has been Jlted wait for minimum 1h before operaJon To return later to the sejngs check the paragraphs Sejng of the installaBon or Parameters of installaBon Check the informaBon Follow the instrucBons Access to sejngs Lock the sejngs Navigate Reduce Increase the values Return to previous screen Confirm MENU 22 Fill the water heater by opening all hot water taps and opening the cold wate...

Page 24: ...rotate the knob a half turn to the right To exit the installer mode proceed in the same way or wait for 3 minutes Access to parameters à à Sejngs rotate 1 2 turn to the right press and hold Air pipes aeraulics operaBon This parameter defines the type of aeraulics connecBon Air intake and exit are not connected to air ducts ambient air Air intake and exit are connected to air ducts fully ducted Air ...

Page 25: ...ater operates only on the electric backup heater CirculaJon cycle This mode is mandatory when a circulaBon loop is installed The set temperature changes to 65 C and the operaBon of the heat pump is adapted to this use The heat pump is allowed to work permanently programming is not available 10 5 FuncJonal check FuncBonal check is available in MODE INSTALLER Press and hold the buTon MENU and turn t...

Page 26: ...ucBon as required It reacts to unplanned events by launching working cycles during the day to assure enough hot water The set temperature varies automaBcally between 50 and 62 C according to the consumpBon profile The water heater chooses preferably the heat pump The electric backup can automaBcally be added to provide the correct hot water volume 10 7 Locking of interface Press for some seconds to...

Page 27: ...gate Reduce Increase the values Return to previous screen Confirm 2 DescripJon of pictograms Fast heaBng confirmed Absence registered in operaBon Present hot water temperature WaiBng Warning Electric backup working Heat pump working Boiler backup working RecepBon of signal on solar system contact RecepBon of signal on photovoltaic Smart grid contact MENU 26 ...

Page 28: ...ing the absence period the water temperature remains above 15 C This funcBon can be interrupted at any moment Stop absence Display the energy savings Allows to display the working level of the heat pump and of the electric backup during the last 7 days the last 12 months since commissioning Display the electric consumpJon Allows to display the energy consumpBon in kw h of the last days the last mo...

Page 29: ...he user between 50 and 62 C The water heater chooses preferably the heat pump The boiler backup can be acBvated automaBcally to provide the correct hot water volume If the backup through the boiler is not available e g boiler switched off the electric backup will be acBvated 4 2 The installaJon mode Boiler backup The water heater works only during the period when the solar system does not supply en...

Page 30: ... valve 1 to 2 Bmes per month Operate the safety valve Check that water evacuaBon is ok General 1 Bme per month Check external shape of your device no Error code displayed no leakage on the connecBons By the INSTALLER What When How Ducts 1 per year Check if the device is ducted Check if the ducts are well posiBoned and not deformed Condensates evacuaBon 1 per year Check the cleanness of the condens...

Page 31: ... Check the correct working of the heat pump Components of the heat pump Every 2 years Check the venBlator operaBon on it s 2 speeds and the hot gas valve Evaporator Every 2 years Clean the evaporator with a nylon brush and products neither scratching nor corrosive Refrigerant Every 5 years Check the refrigerant quanBty By the REFRIGERATION ENGINEER 3 Open the water heater for maintenance In case o...

Page 32: ...ectric backup Resejng automaBcally at T 10 C Control the situaBon of the installaBon room frost free Error 21 Air intake probe defect or out of measuring range HP stopped HeaBng with electric backup Check the connecBons A4 and the posiBon of the air intake probe If necessary replace the probe cable harness Error 22 Evaporator top probe defect or out of measurement range 20 to 110 HP stopped HeaBng...

Page 33: ...t stop more than 24h or lack of power HP stopped HeaBng with electric backup Check the cleanness of the evaporator High consumpBon or circulaBon loop or leak on hot water circuit Check the connecBons A4 and the correct contact of the probes to the tubes Check the charge the overheat value 5 minimum the defrost operaBon Control the resistance of compressor windings Overview InstallaBon OperaBon Mai...

Page 34: ...counter does not exceed 5 bar 0 5 MPa if it does install a pressure reducer set to 3 bar 0 3 MPa at the start of the water network The electric backup heater does not work Mechanical security thermostat was triggered Thermostat defect Backup heater defect Reset the security thermostat on the heaBng element Replacer the thermostat Replace the element Condensate overflow Condensates evacuaBon clogged...

Page 35: ... year in commercial installaBons The compressor is warranted for a period of 5 years in domesBc and 2 years in commercial installaBon 5 Our warranty takes effect from the date of purchase according to invoice and where there is no documentary evidence the date used will be that of manufacture as shown on the water heater informaBon plate plus six months The warranty on the replacement part or water...

Page 36: ...aused by impacts or falls when the hpwh is handled acer leaving the factory 2 Where service is required to reconnect the hpwh operaBon due to problems related with abnormal water supply i e high water pressure above 1 000 kPa before at system pressure relief faulty plumbing supply or downstream connecBon and or electrical wiring or major variaBons in electrical energy supply 3 Failing to ensure th...

Page 37: ...e free life the AtlanBc Heat Pump Water Heater incorporates an impressed current protecBon system normally only found in major installaBons in contact with water such as gas transmission pipelines It is important that the composiBon of water is not excessively high in salt which may result is aggressive aTack or calcium carbonate also known as water hardness which will coat and isolate the effecBve...

Page 38: ...limentaBon permanente Permanente voedingskabel Cable de alimentación permanente Permanent power supply cable Non fournis Niet geleverd No suministrada Not supplied 21 Câble de connexion PV Smart Grid Solaire Kabel communicaBe PV Smart Grid Zonne Cable de conexión PV Smart Grid Solare ConnecBon cable PV Smart Grid Solar 22 Câble de connexion chaudière Kabel ketel Cable de conexión caldera ConnecBon...

Page 39: ... 422 000 FOR WARRANTY REGISTRATION REGISTER AT AUSTRALIA www atlanBcs com au NEW ZEALAND www atlanBc nz WARRANTY Water heater tank DomesBc 10 years 3 years commercial Heat pump DomesBc 5 years 2 years commercial Labour Electrics DomesBc 2 years 1 year commercial Warranty CondiBons Exclusions apply ...

Reviews: