PV system (Photovoltaic)/Smart-‐grid :
This parameter acBvates the pairing of the water heater with a photovoltaic installaBon. This operaBng mode
allows the forced start of the heat pump when the photovoltaic inverter sends a signal to the water heater.
The regulaBon switches automaBcally to the previous operaBng mode 30mn acer the loss of the
photovoltaic signal.
During the signal recepBon the set temperature is automaBcally raised to 62°C (can not be changed).
•
Exhaust air
:
Allows to acBvate the air extracBon funcBon (2 speed : 300 or 390m
3
/h). When the water heater does not
heat the tank, the venBlator turns to evacuate the ambient air to the outside (only possible to acBvate if the
aeraulics connecBon is set to Indoor/Outdoor).
•
AnJ-‐Legionella funcJon
:
Allows to acBvate the funcBon of water disinfecBon several Bmes per month.
The water temperature reaches 62°C one to four Bmes per month depending on the sejng.
•
EMERGENCY-‐mode
:
When acBvated the water heater operates only on the electric backup heater.
•
CirculaJon cycle
:
This mode is mandatory when a circulaBon loop is installed.
The set temperature changes to 65°C and the operaBon of the heat pump is adapted to this use.
The heat pump is allowed to work permanently (programming is not available).
10.5. FuncJonal check
FuncBonal check is available in MODE INSTALLER
Press and hold the buTon MENU and turn the knob half a turn to the
right.
To exit the mode installer, proceed the same way or wait for
10 minutes.
Access to parameters
à
à
à
Test
❷
Rotate
1/2 turn
to the
right
❶ Press and hold
Actuator
Compressor
Start the venBlator then the compressor
Slow operaJon
Operate the venBlator at low speed
Fast operaJon
Operate the venBlator at high speed
DefrosJng valve
Open
Check the click noise of the motor
Compressor + defrosJng.
Start the venBlator then the compressor
and click noise of the hot gas valve
AddiJonal electric backup
Start the electric backup heater
AddiJonal boiler
Close the dry contact commanding the
boiler
Temperature sensor
Display the temperatures : incoming air, top
evaporator, boTom evaporator, exit
compressor, hot water
Fan
The TEST menu allows to operate all components of the product.