6.2. Hot water connecJon
Overview
InstallaBon
OperaBon
Maintenance
Warranty
Do not connect copper tubes directly on the tank connecJon. You have to fit the supplied insulaJon
union (included in the supply).
In case that the tank connecJon is corroded without this protecJon the warranty will not apply.
6.5. Condensate evacuaJon
Depending on the degree of humidity in the air you can get
up to 0,25l/h of condensaBon. The evacuaBon of condensate
should been made directly to the PTR drain point.
The temperature drop of the air passing through the exchanger forms condensaJon from humidity
in the air. The condensed water is evacuated on the rear of the tank using the supplied plasJc tube.
6.3. ConnecJon of circulaJon loop
Do not connect copper tubes directly on the tank connecJon. You have to fit the supplied insulaJon
union (included in the supply).
In case that the tank connecJon is corroded without this protecJon the warranty will not apply.
If the circulaJon connecJon is not used install the plug and seal on this connecJon (included in the
supply).
6.4. ConnecJon of primary circuit (for water heater with coil)
Protect the circuit against over pressure due to water expansion during heaJng with a safety valve 3
bar – 0,3MPa, or an expansion vessel open type (atmospheric pressure) or a closed expansion vessel.
The nominal circuit pressure should not exceed 3 bar – 0,3MPa, the temperature not higher than
85°C. If the coil is connected to solar panels use an adapted water glycol mix to protect against frost
and corrosion : e.g. « TYFOCOR L ». If the circuit is equipped with stop valves on the coil entry and
exit do never close both valves simultaneously to avoid the risk of over-‐pressure in the coil.
17