4. InstallaJon semi – cased (1 duct for air exit).
ü
non heated room with ambient temperature > 5° C and insulated to the
heated rooms of the dwelling.
ü
Parameter « Air pipes » to be set on « Inner/Outer ».
ü
Recommended room = underground or parBally underground, room where
average yearly temperature is > 10° C°.
The pressure reducJon in the room generated by the air extracJon causes fresh air entry through
doors and windows. Plan an air entry (Ø 160mm) from outside to avoid air sucking from heated
living area.
In winter Jme the renewed air can cool the room.
Keep a free space of 500 mm in front of electric compartment and 300 mm around hydraulic
connecJons to allow easy access for maintenance.
620mm
670mm
min
120mm
min
Examples :
•
Garage : recovery of free energy from combusBon engine or of domesBc
devices
•
Washing room : reduce humidity of the room and recover lost energy of
washing machine and dryer.
Inner/Outer
14