INSTALLATION INSTRUCTIONS

412 137

Family 4
No. 4061
Index C
Date 01/2011

VMC

Certification reference guide 

NF205

www.marque-nf.com

Summary of Contents for Duolix Max

Page 1: ...INSTALLATION INSTRUCTIONS 412 137 Family 4 No 4061 Index C Date 01 2011 VMC Certification reference guide NF205 www marque nf com ...

Page 2: ...12 5 4 5 Choosing the night cooling management mode 13 5 4 6 Adjusting the by pass parameters 13 5 4 7 Adjusting the filter s service life 14 5 4 8 Choosing the absence management mode 15 5 4 9 Adjusting the absence flow 15 5 4 10 Defining the connected accessories 16 5 4 11 Defining the thresholds for the ground coupled heat exchanger 16 5 4 12 Finishing configuration 17 6 APPENDIX 18 6 1 Managin...

Page 3: ... Flow manifold on the waste air network resulting in reduced consumption all year round BOOST function Increased flows for better night coolinge Option to manage a ground coupled heat exchanger Numerous possible configurations see appendix Dual flow ventilation enabling the fresh air to be blown into the living rooms bedrooms lounge living room and waste air extracted from the damp rooms kitchen b...

Page 4: ... kg Hook the product on to the strip 3 3 Suspended assembly Mount 4 vertical struts threaded rod and M5 plug so that that the permissible load may reach 120 kg in the designated places on the front of the product Hang the product on the ceiling using these 4 struts ensuring it is horizontal 3 4 Product fitted to the ground Use the 4 optional feet feet part no 809 538 supplied with the accessories ...

Page 5: ...purpose Position the front panel on top of the Duolix MAX with the sides apart and then clip them onto the designated hooks CAUTION Check that no rubble or other foreign bodies risk damaging the fans once they are switched on This product includes two fans Take the necessary precautions to ensure the correct installation of the product and its network in order to avoid any noise disturbance Option...

Page 6: ...EVICE FROM THE MAINS BY SWITCHING THE BI POLAR CIRCUIT BREAKER AND ENSURING THAT THE SUPPLY CANNOT BE RESTORED ACCIDENTALLY THIS EQUIPMENT MUST BE INSTALLED BY PERSONS WITH THE APPROPRIATE QUALIFICATIONS THE INSTALLATION SHOULD COMPLY WITH STANDARD NF C15 100 AND GOOD PROFESSIONAL PRACTICE EACH PRODUCT OR COMPONENT INVOLVED IN INSTALLATION MUST ALSO BE COMPLIANT WITH THE APPLICABLE STANDARDS If th...

Page 7: ... The cable temperature resistance to be used for this connection should be at least 90 C Strip the conductors back 5 to 6 mm in order not to risk them coming into contact with other wires The earth wire green yellow should be longer than the other conductors approx 5 to 10 mm The wires should not be tightened on the insulator The product is equipped with a 2P plug and earth Open the plug Connect P...

Page 8: ... this message does not appear follow the linking procedure 1 Switch off the electrical supply to the Duolix MAX unit directly from a switchboard via the relevant circuit breaker 2 Wait for at least 20 seconds 3 Re establish the electrical supply to the Duolix MAX unit via the circuit breaker 4 Go to within three metres of your Duolix MAX unit with the control In certain exceptional cases loss of l...

Page 9: ...ny support surface For improved stability fold out the rear support in order to place the control in the easel position Mounting on the wall To place the control on a wall the mounting support on the rear needs to be detached first Then mount the support on the wall with the screw not supplied and the plugs suitable for your wall 1 Separate the base from the support 2 Pull to unclip it 3 Use the m...

Page 10: ...ost important as they requiring setting for the house concerned The next pages are optional and refer to specific installations presence of ground connected heat exchanger etc During installation the button enables you to go back to the previous stage During installation the button enables you to skip the next stages and go directly to the end of the configuration menu 5 4 1 Choosing the language ...

Page 11: ...mplying with regulations in force It adjusts the extraction flow and air flow with precision in accordance with the order to activate the large kitchen flow or not To do this it is necessary to provide the unit with two flow values These two values are given in the table below according to the configuration of the house ...

Page 12: ...the choice is confirmed 5 4 3 Adjusting the imbalance Use the navigation arrows and to modify the imbalance Pressing the left arrow reduces the air injection flow for an unchanged extracted air Pressing the right arrow increases the air injection flow for unchanged extracted air Then validate the desired value by pressing When the Ok symbol appears the choice is confirmed 5 4 4 Adjusting the night...

Page 13: ...the parameter needs to be modified N B In all cases this choice does not deactivate the option of manual night cooling if required by the occupant When the following page appears choose Auto so that the Duolix MAX manages night cooling automatically No for no automatic night cooling Use the navigation keys to switch from No to Auto and vice versa Then confirm the choice by pressing When the OK sym...

Page 14: ...tion keys and to increase or reduce the lower threshold value Then confirm the desired value by pressing When the OK symbol appears the choice is confirmed 5 4 7 Adjusting the filter s service life Use the navigation keys and to increase or reduce the filter s service life before the alarm can be adjusted from 8 to 24 months with a factory setting of 12 months Then confirm the desired value by pre...

Page 15: ...he unit then reduces its flowrate in accordance with the programmed value until it detects the return of the occupant see wiring details in the appendix Use the navigation keys and to switch from Man to Auto and vice versa If the sensor option has been chosen and installed select Auto If the option has not been chosen choose Man Then confirm the desired value by pressing When the OK symbol appears...

Page 16: ...configuration 5 4 11 Defining the thresholds for the ground connected heat exchangers The Duolix MAX can control a ground connected heat exchanger valve The principle is to supply the Duolix MAX central unit via the ground connected heat exchanger air inlet when the external air is below the minimum threshold 5 C for example or above the max threshold 25 C for example in order to heat the fresh ai...

Page 17: ...or initialisation Init enabling the factory settings to be returned to If End is selected and confirmed by pressing configuration is complete If Init is selected and confirmed by pressing the following screen is displayed Use the navigation keys and to switch from yes to no Yes reinitialises the parameters to their factory settings No finalises the configuration and saves the previously defined va...

Page 18: ...XP part no 123 084 VCM 200 AXR part no 533 020 Max power of the external night cooling device 100 W with a min 0 9 phi cos Connect the component phase and neutral 230 VAC with the connection kit to the OUT4 terminals 6 2 Option to control the night cooling via a remote switch The Duolix MAX provides the option of controlling the night cooling either internally or externally by the mobile control o...

Page 19: ...fore preferable to pass through the fresh air inlet directly The Duolix MAX controls this valve by managing the source of fresh air used in the house N B These min and max thresholds can be adjusted in accordance with the installation See chapter 5 4 10 6 3 2 Ground connected heat exchanger wiring Connector kit part no 412 093 Ground connected heat exchanger kit All or Nothing valve RR125 M1 part ...

Page 20: ...following connection diagram 6 4 Basic management of an auxiliary 6 4 1 Description of the operation The Duolix MAX enables an auxiliary to be controlled via its mobile control This auxiliary may be an air valve for example See the diagram for the various examples contact us Relevant example Limit the use of the anti frost function to improve the efficiency of the Duolix MAX in cold or very cold r...

Page 21: ...ation If the presence sensor option part no DIP code 323 020 exposed or 323 021 enclosed was chosen and installed the occupant may choose to activate the auto absence mode before leaving The unit reduces its flowrate in accordance with the programmed value until the unit detects the return of the occupant to their house 6 5 2 Presence sensor wiring Duolix MAX circuit board Separate power supply fr...

Page 22: ...22 6 6 Circuit board input output diagram ...

Page 23: ... be performed by a qualified person 6 7 2 Maintenance of the Duolix MAX unit by qualified personnel CAUTION Switch off the electrical supply to the device without fail before opening the protective metal cover Remove the white polymer fascia Unscrew the seven metal fascia screws Remove the exchanger by pulling it towards yourself Place the exchanger in slightly soapy warm water Rinse well Leave it...

Page 24: ... 4 13 25 Church Street Hawthorn Victoria Free Call 1800 677 857 Web www atlantics com au Email sales atlantics com au New Zealand PH 0800 422 000 Web www atlantics co nz Email sales atlantics co nz Head office Atlantic Climatisation et Ventilation 13 Bd Monge ZI BP 71 69882 Meyzieu Cedex Tél 04 72 45 11 00 Fax 04 72 45 11 11 www atlantic pros fr ...