PLUMBING THE SKIMMER 

None of the Big Bahama Pro Series Skimmers come with a pre-drilled pump outlet.  Not 
having a pre-drilled pump outlet gives the professional installer the flexibility to choose which 
side of the enclosure to exit and 
with what size pipe.  
Drill-points have been 
provided on all Big Bahama 
models to show the proper 
location for drilling the 
outlet.  See Figure 8 for 
drill-point locations and 
hole sizes. Using the 
drill-points ensures that 
the pipe outlet will be 
above water level.

Drill-points for the pump discharge are provided on both sides of all Pro Series 
Skimmers. Cut for 2” and 3” pipe are provided on the PS15000 only. 

   2 

½

”        

Hole  Saw   

  

2” PVC     3” PVC

PS4600

  

PS7000

  

PS15000

 

 

   2 

½

”        3 

3/4

Hole Saw   

  

Hole Saw

   2 

½

”        3 

3/4

Hole Saw   

  

Hole Saw

Figure 8.

2” PVC

3” PVC

BULKHEAD INSTALLATION

   It is recommended to install the bulkhead fitting and Male Thread Adapter (MTA) 
(included) before setting the FilterFalls. Big Bahama Pro Series FilterFalls are not pre-drilled 
for the bulkhead fitting. Not having a pre-drilled pipe inlet gives the professional installer 
the flexibility to choose which panel of the FilterFalls to enter. Drill-points have been 
provided to indicate the proper height to drill for the bulkhead fitting. Information has 
been provided below to show which bulkhead is supplied and what size hole saw should be 
used. (Note: If you are installing a BFK100 Back Flush Kit (not included), this is a good time 
to drill for the bulkhead fittings.) See the Back Flush installation instructions on page 14 for 
more information.
   Remove the retaining nut and plastic friction washer, leaving the rubber gasket on the 
body of the bulkhead fitting. Note that the retaining nut is reverse threads. Turn clockwise 
to loosen.
   From the inside of the FilterFalls, insert the threaded 
end of the bulkhead into the hole on the back of 
the enclosure. This will sandwich the rubber gasket 
between the flange of the bulkhead and the inside 
wall of the enclosure. Slip the friction washer over 
the threaded end of the bulkhead on the outside of 
the enclosure and install the retaining nut. Tighten 
the retaining nut by hand and then finish off with a 
half turn from a wrench. Note that the retaining nut is 
reverse threads. Turn counterclockwise to tighten.

Pro Series FilterFalls Installation

BF1900
BF2600
BF3800

2”

Bulkhead

3”

Bulkhead

X
X

X

3”

Hole Saw

4.5”

Hole Saw

MODEL

Summary of Contents for BF1900

Page 1: ...Instruction Manual 1 877 80 PONDS www atlanticwatergardens com...

Page 2: ...mp Vault Page 10 FASTFALLS INSTALLATION Setting the FastFalls Page 11 Liner and Plumbing Attachment Page 11 Hiding the FastFalls Page 12 PRO SERIES ACCESSORIES Bottom Drain Kit Page 12 Back Flush Kit...

Page 3: ...ottom reservoir to the top of the waterfall and or streambed The water must then fill from top to bottom the waterfalls and streambed until it eventually re enters the pond and the water levels equali...

Page 4: ...reambed and enables the system to function optimally Transitional water is determined by the height that the weir rock extends above the liner at the spillway opening Maintaining the shortest distance...

Page 5: ...top of the weir door opening and even with the water level indicator molded on the side of the Skimmer PS15000 only Make sure that any unexcavated soil that is left in front of the Skimmer is at least...

Page 6: ...fasten the top corners using two of the supplied 1 4 20 machine screws and serrated flange nuts Next install two screws in the bottom corners of the weir door frame Once you have the weir door tacked...

Page 7: ...choose which panel of the FilterFalls to enter Drill points have been provided to indicate the proper height to drill for the bulkhead fitting Information has been provided below to show which bulkhe...

Page 8: ...ulkhead until tight Use PVC Glue not included to glue the PVC flex hose into the MTA Do not completely backfill the FilterFalls until all of your plumbing connections are made and the liner has been a...

Page 9: ...can hold before you begin construction of the waterfalls or streambed Why should the basin be three times the size of the stream Upon start up the pump sends water from the bottom reservoir to the top...

Page 10: ...tall underlayment pond liner properly oriented Eco Blox and Pump Vault Backfill the space between the Eco Blox Pump Vault and the excavation to lock them into place either outside the liner with sand...

Page 11: ...ase Place the FastFalls on top of the liner in its original position Check the unit for level to ensure that nothing has changed Once the FastFalls is level and positioned correctly place a couple of...

Page 12: ...ed lip will keep the gravel or soil from washing into the water Pro Series Accessories BOTTOM DRAIN KIT The BD2000 Bottom Drain Kit contains all the necessary fittings to properly install a bottom dra...

Page 13: ...en onto the 2 threaded street 90 and place the screen in its desired location Measure for the correct length of pipe to join the 90 to the MTA that you installed in the pond side of the bulkhead Cut a...

Page 14: ...e hole 21 2 up will position the bulkhead as low as possible Install the bottom drain bulkhead and follow the plumbing diagram below to complete the installation Note Three stage matala filter kits ar...

Page 15: ...ponding Skimmer Pump Vault Use of this equipment combination is not recommended and could void the warranty The discharge pipe can be extended with the 2 PVC pipe and a coupling for use with the large...

Page 16: ...en the retaining nut Figure 23 Fittings to connect the Auto Fill to a garden hose irrigation line and Sch40 PVC are included in the kit Wrap the male threads on the Auto Fill with thread sealant and i...

Reviews: