Use a small piece of sandpaper to smooth out the cut end of the discharge pipe. 
Clean the 2” socket fitting on the bottom of the check valve and the cut end of the 
discharge pipe with PVC cleaner/primer. Apply PVC glue and insert the discharge 
pipe into the 2” socket fitting. Hold the discharge pipe firmly in place for a few 
seconds, giving the glue time to set (Figure 21).

Figure 20.

DISCHARGE PIPE ‘PERFECT CUT’ 
REFERENCE CHART

D

D

D

C

C

2

G

G

G

F

F

5

B

B

B

A

A

1

TW1200

TW1900

TW2400

TW3700

TW4800

TW6000

5

5

5

5

7

7

7

7

3

3

3

3

PAF-20

PAF-25

PAF-40

PAF-75

5

4

7

6

3

2

A-05

A-21

PRO SERIES PRODUCTS

PS4600

G

G

G

D

D

H

H

H

G

G

E

E

E

B

B

PS7000

PV1800

SH1450

SH2050

SH3600

SH5000

SH6500

Shaded areas denote pumps that exceed 
maximum flow rates or dimension for use 
with the corresponding Skimmer/Pump 
Vault. Use of this equipment combination 
is not recommended and could void the 
warranty.

* The discharge pipe can be extended with 
the 2" PVC pipe and a coupling for use with 
the larger/deeper Big Bahama products 
(PV2300/PS15000) or Pump Vaults 
with extensions.

Figure 21.

  Locate the correct reference mark for this 
installation on the discharge pipe. Using a 
hacksaw or PVC saw, cut the pipe at this mark 
being careful to make a clean, square cut (Fig-
ure 20). Discard the end of the discharge pipe 
that will not be used.

If you have removed the outlet fitting from the check valve prior to gluing 

the connection, make sure to slide the union nut onto the supply pipe 

before gluing the socket fitting in place.

MD, TW2 and SH Series pumps include fittings that convert the pump discharge to 1 ½” female 
threads and are neccessary for proper attachment to the TR215CV.

Attach the Triton Check Valve to the TidalWave pump by threading the 
discharge pipe into the pump discharge.

Summary of Contents for BF1900

Page 1: ...Instruction Manual 1 877 80 PONDS www atlanticwatergardens com...

Page 2: ...mp Vault Page 10 FASTFALLS INSTALLATION Setting the FastFalls Page 11 Liner and Plumbing Attachment Page 11 Hiding the FastFalls Page 12 PRO SERIES ACCESSORIES Bottom Drain Kit Page 12 Back Flush Kit...

Page 3: ...ottom reservoir to the top of the waterfall and or streambed The water must then fill from top to bottom the waterfalls and streambed until it eventually re enters the pond and the water levels equali...

Page 4: ...reambed and enables the system to function optimally Transitional water is determined by the height that the weir rock extends above the liner at the spillway opening Maintaining the shortest distance...

Page 5: ...top of the weir door opening and even with the water level indicator molded on the side of the Skimmer PS15000 only Make sure that any unexcavated soil that is left in front of the Skimmer is at least...

Page 6: ...fasten the top corners using two of the supplied 1 4 20 machine screws and serrated flange nuts Next install two screws in the bottom corners of the weir door frame Once you have the weir door tacked...

Page 7: ...choose which panel of the FilterFalls to enter Drill points have been provided to indicate the proper height to drill for the bulkhead fitting Information has been provided below to show which bulkhe...

Page 8: ...ulkhead until tight Use PVC Glue not included to glue the PVC flex hose into the MTA Do not completely backfill the FilterFalls until all of your plumbing connections are made and the liner has been a...

Page 9: ...can hold before you begin construction of the waterfalls or streambed Why should the basin be three times the size of the stream Upon start up the pump sends water from the bottom reservoir to the top...

Page 10: ...tall underlayment pond liner properly oriented Eco Blox and Pump Vault Backfill the space between the Eco Blox Pump Vault and the excavation to lock them into place either outside the liner with sand...

Page 11: ...ase Place the FastFalls on top of the liner in its original position Check the unit for level to ensure that nothing has changed Once the FastFalls is level and positioned correctly place a couple of...

Page 12: ...ed lip will keep the gravel or soil from washing into the water Pro Series Accessories BOTTOM DRAIN KIT The BD2000 Bottom Drain Kit contains all the necessary fittings to properly install a bottom dra...

Page 13: ...en onto the 2 threaded street 90 and place the screen in its desired location Measure for the correct length of pipe to join the 90 to the MTA that you installed in the pond side of the bulkhead Cut a...

Page 14: ...e hole 21 2 up will position the bulkhead as low as possible Install the bottom drain bulkhead and follow the plumbing diagram below to complete the installation Note Three stage matala filter kits ar...

Page 15: ...ponding Skimmer Pump Vault Use of this equipment combination is not recommended and could void the warranty The discharge pipe can be extended with the 2 PVC pipe and a coupling for use with the large...

Page 16: ...en the retaining nut Figure 23 Fittings to connect the Auto Fill to a garden hose irrigation line and Sch40 PVC are included in the kit Wrap the male threads on the Auto Fill with thread sealant and i...

Reviews: