Atlantic BF1900 Instruction Manual Download Page 14

BACK FLUSH KIT

 

If you are installing the BFK1000 in a new construction project it is a good idea to 

drill the holes and install the 2” bulkheads and male thread adaptors before you set the 
FilterFalls. Drill-points have been provided below the rock ledge on two of the back filter 
panels for the back-flush feed inlets. Drill the holes using a 3” hole saw and install the 
bulkheads. Follow the bulkhead installation instructions on page 7.
  Find the best location for the bottom drain outlet. Drill-points are not provided for the 
bottom drain bulkhead location. The bottom drain can be installed in any of the open 
panels on the bottom of  the FilterFalls. The center point of hole should be drilled 2

1/2”

 up 

from the bottom of the FilterFalls and centered from side to side on one of the panels. 
Drilling the hole 2

1/2”

 up will position the bulkhead as low as possible.

  Install the bottom drain bulkhead and follow the plumbing diagram below to complete 
the installation. Note: Three stage matala filter kits are available for all Pro Series 
FilterFalls. Matala filters will greatly increase the effectiveness of the back-flush kit.

PUMP

DISCHARGE

FILTERFALL FEED

BACK FLUSH FEED

DRAIN

BACK FLUSH FEED

3” HOLES

3” HOLE

3” HOLE

MAIN FEED

BOTTOM 
DRAIN

1

/

2

Figure 19.

Locate the model number of the Atlantic Skimmer/Pump Vault and TidalWave pump used 
for this installation on the chart on the next page. Follow the corresponding column down 
and row across until they intersect. The number or letter at the intersection point is the 
‘perfect cut’ reference mark for this installation. If the corresponding reference mark is a 
letter, then the 1½" threaded end of the discharge pipe will be used. If the corresponding 
reference mark is a number, then the 2" threaded end of the discharge pipe will be used.

TRITON CHECK VALVE

14

Summary of Contents for BF1900

Page 1: ...Instruction Manual 1 877 80 PONDS www atlanticwatergardens com...

Page 2: ...mp Vault Page 10 FASTFALLS INSTALLATION Setting the FastFalls Page 11 Liner and Plumbing Attachment Page 11 Hiding the FastFalls Page 12 PRO SERIES ACCESSORIES Bottom Drain Kit Page 12 Back Flush Kit...

Page 3: ...ottom reservoir to the top of the waterfall and or streambed The water must then fill from top to bottom the waterfalls and streambed until it eventually re enters the pond and the water levels equali...

Page 4: ...reambed and enables the system to function optimally Transitional water is determined by the height that the weir rock extends above the liner at the spillway opening Maintaining the shortest distance...

Page 5: ...top of the weir door opening and even with the water level indicator molded on the side of the Skimmer PS15000 only Make sure that any unexcavated soil that is left in front of the Skimmer is at least...

Page 6: ...fasten the top corners using two of the supplied 1 4 20 machine screws and serrated flange nuts Next install two screws in the bottom corners of the weir door frame Once you have the weir door tacked...

Page 7: ...choose which panel of the FilterFalls to enter Drill points have been provided to indicate the proper height to drill for the bulkhead fitting Information has been provided below to show which bulkhe...

Page 8: ...ulkhead until tight Use PVC Glue not included to glue the PVC flex hose into the MTA Do not completely backfill the FilterFalls until all of your plumbing connections are made and the liner has been a...

Page 9: ...can hold before you begin construction of the waterfalls or streambed Why should the basin be three times the size of the stream Upon start up the pump sends water from the bottom reservoir to the top...

Page 10: ...tall underlayment pond liner properly oriented Eco Blox and Pump Vault Backfill the space between the Eco Blox Pump Vault and the excavation to lock them into place either outside the liner with sand...

Page 11: ...ase Place the FastFalls on top of the liner in its original position Check the unit for level to ensure that nothing has changed Once the FastFalls is level and positioned correctly place a couple of...

Page 12: ...ed lip will keep the gravel or soil from washing into the water Pro Series Accessories BOTTOM DRAIN KIT The BD2000 Bottom Drain Kit contains all the necessary fittings to properly install a bottom dra...

Page 13: ...en onto the 2 threaded street 90 and place the screen in its desired location Measure for the correct length of pipe to join the 90 to the MTA that you installed in the pond side of the bulkhead Cut a...

Page 14: ...e hole 21 2 up will position the bulkhead as low as possible Install the bottom drain bulkhead and follow the plumbing diagram below to complete the installation Note Three stage matala filter kits ar...

Page 15: ...ponding Skimmer Pump Vault Use of this equipment combination is not recommended and could void the warranty The discharge pipe can be extended with the 2 PVC pipe and a coupling for use with the large...

Page 16: ...en the retaining nut Figure 23 Fittings to connect the Auto Fill to a garden hose irrigation line and Sch40 PVC are included in the kit Wrap the male threads on the Auto Fill with thread sealant and i...

Reviews: