Trade name / Models : atlantic
geolia 13
geolia 17
Reference
522455
522456
Space heating application
35°C
55°C
35°C
55°C
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
COP
d
-
5 17
3 43
5 42
3 76
Tj = +2°C
COP
d
-
5 50
4 35
5 68
4 64
Tj = +7°C
COP
d
-
5 81
4 92
5 94
5 18
Tj = +12°C
COP
d
-
6 14
5 51
6 20
5 72
Tj = bivalent temperature
COP
d
-
5 17
3 43
5 42
3 76
Tj = operation limit temperature
COP
d
-
5 11
3 11
5 29
3 54
Heating water operating limit temperature
WTOL
°C
55
Supplementary heater
Rated heat output
(2)
P
sup
kW
2 1
2 1
3 0
2 9
Type of energy input
-
-
Electrical
Other items
Capacity control
-
-
All or nothing
Rated brine flow rate in outdoor heat exchanger
-
m
3
/h
3 71
2 65
5 05
4 10
Brine/water information
Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Pdh
kW
12 6
11 9
17 0
15 7
Tj = +2°C
Pdh
kW
12 7
12 2
17 1
16 3
Tj = +7°C
Pdh
kW
12 8
12 4
17 2
16 7
Tj = +12°C
Pdh
kW
12 9
12 6
17 3
17 0
Tj = bivalent temperature
Pdh
kW
12 6
11 9
17 0
15 7
Tj = operation limit temperature
Pdh
kW
12 6
11 9
16 5
15 4
Degradation coefficient
Cdh
(3)
-
0 99
Bivalent temperature
T
biv
°C
-7
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
COP
d
-
4 53
3 43
4 48
2 97
Tj = +2°C
COP
d
-
4 70
3 65
4 68
3 58
Tj = +7°C
COP
d
-
4 86
4 07
4 88
3 95
Tj = +12°C
COP
d
-
5 02
4 47
5 08
4 32
Tj = bivalent temperature
COP
d
-
4 53
3 43
4 48
2 97
Tj = operation limit temperature
COP
d
-
4 26
2 86
4 22
2 74
Heating water operating limit temperature
WTOL
°C
55
Supplementary heater
Rated heat output
(2)
P
sup
kW
1 7
1 6
2 7
2 3
Type of energy input
-
-
Electrical
Other items
Capacity control
-
-
All or nothing
Rated brine flow rate in outdoor heat exchanger
-
m
3
/h
2 86
2 28
3 73
2 90
Water/water and brine/water information
Power consumption in modes other than active mode
Off mode
P
OFF
kW
0 002
0 002
Thermostat-off mode
PTO
kW
0 090
0 090
Standby mode
P
SB
kW
0 003
0 003
Crankcase heater mode
P
CK
kW
0 000
0 000
(1)
Seasonal
efficiency calculation is detailed in package fiche - room units are available as option and includes: thermostat and room sensors, room unit controller wether
they are, or not, integrated in kits.
(2)
For
heat pump space heaters and heat pump combination heaters, the rated heat output P
rated
is equal to the design load for heating P
designh
, and the rated heat output
of the supplementary heater P
sup
is equal to the supplementary capacity for heating sup(Tj).
(3)
If
Cdh is not determinated by measurement then the default degradation coefficient is Cdh=0.9.
Operation manual "1639 - EN"
- 29 -
Ground source heat pump atlantic geolia